Suppr超能文献

基于酒精的洗手液产生的蒸汽对在用口罩过滤性能的降解及缓解方案

Filtration Performance Degradation of In-Use Masks by Vapors from Alcohol-Based Hand Sanitizers and the Mitigation Solutions.

作者信息

He Weidong, Guo Yinghe, Liu Jingxian, Yue Yang, Wang Jing

机构信息

Filter Test Center Northeastern University Shenyang Liaoning CN-110819 China.

Institute of Environmental Engineering ETH Zürich Zürich CH-8093 Switzerland.

出版信息

Glob Chall. 2021 Jun 27;5(9):2100015. doi: 10.1002/gch2.202100015. eCollection 2021 Sep.

Abstract

In the current COVID-19 pandemic, wearing masks and hand disinfection are widely adopted hygiene practices. Alcohol-based sanitizers are commonly used for hand disinfection, however, the alcohol vapors can dissipate the charges on electrostatic filters. In the present study, the effects of alcohol vapors from alcohol-based sanitizers during hand disinfection on the in-use masks are studied. The results show that the negative effects are not significant for nonelectrostatic cotton masks or N95 respirators with multiple charged layers, but noticeable for surgical masks. After five rounds of hand disinfection, the filtration efficiencies of the filtering materials of the surgical masks decrease by more than 8% for 400 and 500 nm particles and by 3.7 ± 1.8% for 1 µm particles, the effective filtration efficiency of the surgical masks worn by the volunteers (with leakage considered) decreases by about 5% for ambient aerosol. In another process to imitate intensive disinfection procedures by healthcare workers, a 30 min surface cleaning process using alcohol-based sanitizer is performed, and the effective efficiency of the N95 respirators worn by the volunteers decreases by nearly 9%. The simple practice of avoiding vapor during hand disinfection could mitigate the effects of alcohol vapor, which is demonstrated on two brands of surgical masks.

摘要

在当前的新冠疫情中,佩戴口罩和手部消毒是广泛采用的卫生措施。酒精类消毒剂常用于手部消毒,然而,酒精蒸汽会使静电过滤器上的电荷消散。在本研究中,对手部消毒过程中酒精类消毒剂产生的酒精蒸汽对在用口罩的影响进行了研究。结果表明,对于非静电棉布口罩或具有多层带电层的N95口罩,负面影响不显著,但对于外科口罩则较为明显。经过五轮手部消毒后,外科口罩过滤材料对400和500纳米颗粒的过滤效率下降超过8%,对1微米颗粒的过滤效率下降3.7±1.8%,志愿者佩戴的外科口罩(考虑泄漏情况)对环境气溶胶的有效过滤效率下降约5%。在另一个模拟医护人员强化消毒程序的过程中,使用酒精类消毒剂进行了30分钟的表面清洁处理,志愿者佩戴的N95口罩的有效效率下降了近9%。在两种品牌的外科口罩上都证明,手部消毒时避免蒸汽的简单做法可以减轻酒精蒸汽的影响。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4e70/8414512/cf6149055991/GCH2-5-2100015-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验