两种不同型号单焦点人工晶状体白内障手术后人工晶状体位置的中期变化与屈光之间的关系

Relationship between Medium-Term Changes in Intraocular Lens Position and Refraction after Cataract Surgery with Two Different Models of Monofocal Lenses.

作者信息

Fukumitsu Hideki, Camps Vicent J, Miraflores Sara, Piñero David P

机构信息

Department of Ophthalmology, Marina Baixa Hospital, 03570 Alicante, Spain.

Department of Ophthalmology, Vithas Medimar International Hospital, 03016 Alicante, Spain.

出版信息

J Clin Med. 2021 Aug 27;10(17):3856. doi: 10.3390/jcm10173856.

Abstract

The aim of this prospective descriptive study was to characterize the variations of the clinical effective lens position (ELP) (considering paraxial optics and postoperative data) and the intraocular lens (IOL) position, using "eye" data gathered from a 6-month follow-up of patients who underwent uneventful cataract surgery. Patients were implanted with two different monofocal IOLs: AcrySof IQ SN60WF (Alcon) (Group 1, 247 eyes) and Akreos MI60L (Bausch & Lomb) (Group 2, 104 eyes). No significant differences were found between groups concerning spherical equivalent (SE), axial length, and clinical ELP changes, from 1 to 6 months after surgery ( ≥ 0.516). A more positive change in postoperative anterior chamber depth was found in Group 2, but the difference did not reach statistical significance ( = 0.065). No significant moderate to strong correlations were found between the changes in clinical ELP and preoperative data. The correlation between the changes in SE and clinical ELP over time was strong and statistically significant (groups 1 and 2: = 0.957 and = 0.993, < 0.001). In conclusion, changes in refraction from 1 to 6 months after cataract surgery, with single-piece monofocal IOLs, are not clinically relevant, which correlates with the presence of good positional stability. These changes cannot be predicted preoperatively and considered in IOL power calculations.

摘要

这项前瞻性描述性研究的目的是,利用对接受了顺利白内障手术的患者进行6个月随访收集的“眼部”数据,来描述临床有效晶状体位置(ELP)(考虑近轴光学和术后数据)及人工晶状体(IOL)位置的变化。患者被植入两种不同的单焦点IOL:AcrySof IQ SN60WF(爱尔康)(第1组,247只眼)和Akreos MI60L(博士伦)(第2组,104只眼)。术后1至6个月,两组在等效球镜度(SE)、眼轴长度和临床ELP变化方面未发现显著差异(≥0.516)。第2组术后前房深度有更正向的变化,但差异未达到统计学显著性(P = 0.065)。临床ELP变化与术前数据之间未发现显著的中度至强相关性。随时间推移,SE变化与临床ELP之间的相关性很强且具有统计学显著性(第1组和第2组:P = 0.957和P = 0.993,P < 0.001)。总之,白内障手术后1至6个月,使用单片单焦点IOL时,屈光变化在临床上并不相关,这与良好的位置稳定性有关。这些变化术前无法预测,也不能在IOL屈光度计算中予以考虑。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f869/8432092/7d063b8014b9/jcm-10-03856-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验