J Refract Surg. 2021 Sep;37(9):636-641. doi: 10.3928/1081597X-20210610-06. Epub 2021 Sep 1.
To examine the vault size after Implantable Collamer Lens (ICL) (KS-AquaPORT; STAAR Surgical) surgery using the KS formula.
In this prospective study, the postoperative vault was examined using the KS formula in 121 eyes of 65 patients (28 men and 37 women) who underwent ICL implantation for myopia and myopic astigmatism. The mean horizontal angle-to-angle (ATA), anterior chamber depth, and axial length before surgery were 11.83 ± 0.40, 3.25 ± 0.34, and 26.52 ± 1.17, respectively. Anterior segment optical coherence tomography (CASIA2; Tomey Corporation) was used for ATA measurement.
Multiple regression analysis of the potential factors influencing the predicted vault error (postoperative vault - predicted vault by KS formula) showed that only ICL size was a significant factor ( < .001, = 0.36). At an ICL size of 12.1 mm, the postoperative vault was smaller than the predicted vault, and the postoperative vault tended to be larger than the predicted vault at ICL sizes of 13.2 and 13.7 mm.
Vault prediction by the KS formula was generally good, but the ICL size influenced the vault prediction error; therefore, a modified KS formula was created to reduce the error in measurements of the postoperative vault. .
使用 KS 公式评估可植入 Collamer 透镜(ICL)(KS-AquaPORT;STAAR Surgical)手术后的拱顶大小。
在这项前瞻性研究中,对 65 名患者(28 名男性和 37 名女性)的 121 只眼进行了 ICL 植入术以治疗近视和近视散光,使用 KS 公式检查术后拱顶。手术前的平均水平角度到角度(ATA)、前房深度和眼轴长度分别为 11.83±0.40、3.25±0.34 和 26.52±1.17。ATA 测量使用前节光学相干断层扫描(CASIA2;Tomey Corporation)。
对影响预测拱顶误差(术后拱顶 - KS 公式预测拱顶)的潜在因素的多元回归分析表明,只有 ICL 尺寸是一个重要因素(<0.001,=0.36)。在 ICL 尺寸为 12.1mm 时,术后拱顶小于预测拱顶,而在 ICL 尺寸为 13.2 和 13.7mm 时,术后拱顶倾向于大于预测拱顶。
KS 公式的拱顶预测通常较好,但 ICL 尺寸会影响拱顶预测误差;因此,创建了一个改良的 KS 公式来减少术后拱顶测量的误差。