Suppr超能文献

Tecnis Symfony ZXR00 型扩展景深人工晶状体与 Tecnis Eyhance ICB00 新型增强中间视力的单焦点人工晶状体的比较

Comparison Between an Intraocular Lens With Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens With Enhanced Intermediate Vision (Tecnis Eyhance ICB00).

机构信息

Department of Opthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea.

Department of Opthalmology, Severance Eye Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.

出版信息

Asia Pac J Ophthalmol (Phila). 2021 Oct 1;10(6):542-547. doi: 10.1097/APO.0000000000000439. Print 2021 Nov-Dec.

Abstract

PURPOSE

This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis Symfony, Johnson & Johnson Vision, Santa Ana, CA, US) to a novel, higher-order aspheric monofocal IOL (ICB00; Tecnis Eyhance, Johnson & Johnson Vision, Santa Ana, CA, US) which uses the same platform and material.

METHODS

Medical records of patients undergoing cataract surgery with ZXR00 or ICB00 implantation between March 2020 and January 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA); corrected distance VA; and optical quality parameters were the main outcome measures.

RESULTS

Among the 174 enrolled patients, 72 and 102 received the ZXR00 and ICB00, respectively. The average patient ages were 59.6 ± 10.6 (range: 49 to 70) and 65.2 ± 8.2 (range: 45 to 82) years in the ZXR00 and ICB00 groups, respectively, with significantly older patients in the ICB00 group. The other baseline parameters were not different for the 2 groups. Compared to the ICB00 group, the ZXR00 group showed markedly superior near VA (P < 0.05) at 3 months postoperatively. In terms of optical quality, ICB00 was, statistically, significantly superior to ZXR00.

CONCLUSIONS

The ZXR00 showed remarkable near vision and defocus curve smoothness, while the ICB00 achieved better optical quality. The 2 IOLs had comparable distance and intermediate vision.

摘要

目的

本研究比较了扩展景深(EDOF)人工晶状体(IOL)(ZXR00;Tecnis Symfony,强生视力,美国圣安娜)与新型、高阶非球面单焦点 IOL(ICB00;Tecnis Eyhance,强生视力,美国圣安娜),两者使用相同的平台和材料。

方法

回顾了 2020 年 3 月至 2021 年 1 月期间接受 ZXR00 或 ICB00 植入白内障手术的患者的病历,并且这些患者在 3 个月随访时的数据可用。未矫正的近、中、远距离视力(VA);矫正的远距离 VA;和光学质量参数是主要的观察指标。

结果

在纳入的 174 名患者中,72 名和 102 名分别接受了 ZXR00 和 ICB00。ZXR00 和 ICB00 组的平均患者年龄分别为 59.6±10.6(范围:49 至 70)和 65.2±8.2(范围:45 至 82)岁,ICB00 组患者年龄明显较大。两组的其他基线参数没有差异。与 ICB00 组相比,ZXR00 组在术后 3 个月时表现出明显更好的近视力(P<0.05)。在光学质量方面,ICB00 在统计学上明显优于 ZXR00。

结论

ZXR00 具有显著的近视力和离焦曲线平滑度,而 ICB00 则具有更好的光学质量。两种 IOL 在远距离和中间距离视力方面相当。