From the Department of Ophthalmology, Vita-Salute University, IRCCS San Raffaele Scientific Institute, Milan, Italy.
J Cataract Refract Surg. 2022 Jan 1;48(1):67-74. doi: 10.1097/j.jcrs.0000000000000706.
To compare the visual performance, spectacle independence, and subjective visual quality of 3 intraocular lenses (IOLs): monofocal, enhanced monofocal, and extended depth of focus.
Ophthalmology Department, San Raffaele Scientific Institute, Milan, Italy.
Prospective case series.
Patients without ocular comorbidities and corneal astigmatism <0.75 diopters (D) undergoing cataract surgery with bilateral implantation of monofocal Tecnis ZCB00, enhanced monofocal Eyhance ICB00, and extended depth-of-focus Symfony ZXR00 IOLs were included. 6 months postoperatively, the following parameters were analyzed: subjective and objective refraction; monocular and binocular corrected distance (4 m) and uncorrected distance (UDVA) visual acuity; corrected distance, intermediate (66 cm), and near (40 cm) visual acuities, as well as uncorrected intermediate (UIVA) and uncorrected near (UNVA) visual acuities; photopic contrast sensitivity; binocular defocus curve; halo and glare perception; and spectacle independence.
150 eyes of 75 patients (25 patients per IOL group) were evaluated. Monocular and binocular UDVA was excellent in all 3 groups. Eyhance achieved binocular UIVA similar to that of Symfony, the latter showing the highest binocular UNVA. The defocus curves at -1.0 D were equivalent for both Eyhance and Symfony, whereas contrast sensitivity was similar in all 3 groups. The Eyhance spectacle independence score was comparable with Symfony for intermediate distance activities, the latter, however, achieved the worst results for halos and glare.
Enhanced monofocal Eyhance was not inferior to Symfony as regards intermediate distance visual outcome and spectacle independence, and also provided lower subjective perception of halos and glare.
比较 3 种人工晶状体(IOL)的视觉性能、离焦独立和主观视觉质量:单焦点、增强型单焦点和扩展景深。
意大利米兰圣拉斐尔科学研究所眼科。
前瞻性病例系列。
纳入无眼部合并症且角膜散光<0.75 屈光度(D)的患者,行白内障手术,双侧植入单焦点 Tecnis ZCB00、增强型单焦点 Eyhance ICB00 和扩展景深 Symfony ZXR00 IOL。术后 6 个月,分析以下参数:主观和客观屈光;单眼和双眼矫正距离(4 m)和未矫正距离(UDVA)视力;矫正距离、中间(66 cm)和近(40 cm)视力,以及未矫正中间(UIVA)和未矫正近(UNVA)视力;明视对比度敏感度;双眼离焦曲线;光晕和眩光感知;以及离焦独立。
75 例患者(每组 25 例)的 150 只眼接受了评估。3 组单眼和双眼 UDVA 均极佳。Eyhance 达到了与 Symfony 相似的双眼 UIVA,后者显示出最高的双眼 UNVA。Eyhance 和 Symfony 在-1.0 D 的离焦曲线相当,而所有 3 组的对比度敏感度相似。Eyhance 的离焦独立评分在中间距离活动方面与 Symfony 相当,后者在光晕和眩光方面的结果最差。
增强型单焦点 Eyhance 在中间距离视力结果和离焦独立方面不逊于 Symfony,并且对光晕和眩光的主观感知也较低。