Abstract

We assessed the performance of the Panbio rapid antigen detection (RAD) test for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and we compared it with the routine reverse transcriptase-polymerase chain reaction (RT-PCR)-based molecular test in a population of 4167 unselected patients admitted to IRCCS Sacro Cuore Don Calabria Hospital. Analysis stratified by cycling threshold (C ) value of SARS-CoV-2 gene targets indicated that antigen (Ag)-positive C values were significantly lower compared to Ag-negative values (p < 0.0001). Overall, we found discordance in 140, tested negative by RAD and positive by RT-PCR, and in 4 resulted positive by RAD and negative by RT-PCR. RAD test achieved a sensitivity and specificity of 66.82% and 99.89%, respectively. The positive predictive value was shown to be 97.87% while the negative predictive value was shown to be 97.62%. In our context, the RAD test showed a reliable diagnostic response in subjects that displayed high C values, corresponding to high viral load, while low ability was displayed to identify positive cases with medium-low C values, thus presenting low viral load and where confirmatory RT-PCR was needed. Our finding supports the use of the RAD test in real-life settings where a high volume of swabs is being processed but with caution when interpreting a positive test result in a low prevalence setting.

摘要

我们评估了 Panbio 快速抗原检测(RAD)试验检测严重急性呼吸综合征冠状病毒 2(SARS-CoV-2)感染的性能,并将其与常规基于逆转录-聚合酶链反应(RT-PCR)的分子试验在 4167 名未选择的入住 IRCCS Sacro Cuore Don Calabria 医院的患者中进行了比较。按 SARS-CoV-2 基因靶标循环阈值(C)值分层分析表明,抗原(Ag)阳性 C 值明显低于 Ag 阴性值(p<0.0001)。总体而言,我们发现 140 例经 RAD 检测为阴性而 RT-PCR 检测为阳性,4 例经 RAD 检测为阳性而 RT-PCR 检测为阴性的结果不一致。RAD 试验的敏感性和特异性分别为 66.82%和 99.89%。阳性预测值为 97.87%,阴性预测值为 97.62%。在我们的研究中,RAD 试验在显示高 C 值的受试者中表现出可靠的诊断反应,这对应于高病毒载量,而在识别 C 值中低病毒载量的阳性病例时显示出低能力,因此需要进行确认性 RT-PCR。我们的研究结果支持在需要处理大量拭子的实际环境中使用 RAD 试验,但在低流行环境中解释阳性检测结果时需要谨慎。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a581/8661633/b4ffe343af12/JMV-94-1190-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验