Suppr超能文献

白内障手术后三焦点 Panoptix®人工晶状体植入的视觉和满意度结果。

Visual and satisfaction results with implantation of the trifocal Panoptix® intraocular lens in cataract surgery.

机构信息

Centro Oftalmológico Virgilio Galvis, Floridablanca, Colombia; Fundación Oftalmológica de Santander FOSCAL, Floridablanca, Colombia; Universidad Autónoma de Bucaramanga UNAB, Bucaramanga, Colombia.

Fundación Oftalmológica de Santander FOSCAL, Floridablanca, Colombia; Universidad Autónoma de Bucaramanga UNAB, Bucaramanga, Colombia.

出版信息

J Optom. 2022 Jul-Sep;15(3):219-227. doi: 10.1016/j.optom.2021.05.002. Epub 2021 Oct 18.

Abstract

PURPOSE

To assess visual results (including the Lapid-Kushlin defocus coefficient), and satisfaction, following the implantation of PanOptix® a trifocal intraocular lens.

METHODS

Observational, retrospective cohort study. 130 eyes of 65 subjects with bilateral implantation were included. Binocular uncorrected visual acuities [distance (Binocular UDVA), intermediate (Binocular UIVA) and near (Binocular UNVA)] were measured. Also, the manifest refraction, binocular defocus curve and binocular contrast sensitivity were determined. The Lapid-Kushlin defocus coefficient, a new single numerical parameter based on the area under the curve of the defocus curve, was calculated. The validated Spanish CATQUEST-9SF satisfaction survey was applied.

RESULTS

Postoperative visual acuity ranges were: binocular UDVA 0.18 to 0.0 LogMAR, binocular UIVA 0.30 to 0.0 LogMAR and Binocular UNVA 0.18 to 0.0 LogMAR. The levels of contrast sensitivity both in bright light conditions (with and without glare) and low light conditions with glare, remained within the limits of normality. Under scotopic conditions without glare values below normality were found at lower spatial frequencies. The binocular defocus curve showed a plateau without a clearly evident peak. The Lapid-Kushlin defocus coefficient was 0.199. Two patients (3.1%) needed glasses after the procedure for near and intermediate vision. No patient manifested great visual difficulties or was dissatisfied with the results.

CONCLUSIONS

The trifocal platform showed very good results in this series of patients. 96.9% of the patients achieved independence of the glasses and expressed a high degree of satisfaction. The Lapid-Kushlin defocus coefficient was better than those calculated from literature, for other multifocal intraocular lenses.

摘要

目的

评估 PanOptix®三焦点人工晶状体植入术后的视觉效果(包括 Lapid-Kushlin 离焦系数)和满意度。

方法

观察性、回顾性队列研究。纳入了 65 名双侧植入患者的 130 只眼。测量双眼未矫正视力[远距(双眼远距视力,Binocular UDVA)、中距(双眼中距视力,Binocular UIVA)和近距(双眼近距视力,Binocular UNVA)]。还测定了客观屈光度、双眼离焦曲线和双眼对比敏感度。计算了一种新的基于离焦曲线下面积的单一数值参数 Lapid-Kushlin 离焦系数。应用经过验证的西班牙 CATQUEST-9SF 满意度调查。

结果

术后视力范围为:双眼 UDVA 0.18 至 0.0 LogMAR,双眼 UIVA 0.30 至 0.0 LogMAR 和双眼 UNVA 0.18 至 0.0 LogMAR。在明亮条件下(有眩光和无眩光)和低光条件下有眩光时,对比敏感度均保持在正常范围内。在无眩光的暗视条件下,较低空间频率的数值低于正常值。双眼离焦曲线呈平台状,没有明显的峰值。Lapid-Kushlin 离焦系数为 0.199。术后有 2 名(3.1%)患者需要远近视力眼镜。没有患者出现明显的视觉困难或对结果不满意。

结论

在本系列患者中,三焦点平台显示出非常好的效果。96.9%的患者实现了对眼镜的独立,并且表达了高度的满意度。Lapid-Kushlin 离焦系数优于其他多焦点人工晶状体文献中计算出的系数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/bc90/9237585/23e0f6914871/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验