Department of Orthodontics, Dental School, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Department of Orthodontics, Dental School, Shahed University, Tehran, Iran.
Am J Orthod Dentofacial Orthop. 2022 Feb;161(2):e172-e186. doi: 10.1016/j.ajodo.2021.07.011. Epub 2021 Oct 20.
Applying root torque using conventional methods (rectangular wire) has side effects such as inverse and destructive forces, undesirable torque on adjacent teeth, heavy forces that are limited in range and duration, and needing too many sessions. We introduce a new method (a horizontal box loop [HBL]) that is designed to reduce many of these side effects; we tested its efficiency and side effects using finite element analysis.
An HBL was created from a 0.018-in round stainless steel archwire, in the form of an equilateral triangle of 7 mm sides, for the permanent maxillary left central incisor. As a control, a SS rectangular wire (19 × 25-in) was used. First, a pilot simulation was performed to standardize the torque in both models as 31.099 N mm. The extent of twisting by the rectangular wire, of which the same amount of moment would be applied, was estimated at 28.282°. The main study evaluated the effects of the 31.099 N.mm moments applied by both models to the left central incisor on stresses, dental movements (buccolingually, mesiodistally, and extrusive or intrusive), and intercanine or intermolar widths.
Under standardized conditions, the HBL causes a greater palatal root torque of the central incisor than the rectangular wire. The HBL does not apply reverse root torque on adjacent teeth, whereas the rectangular wire causes reverse root torque in neighboring teeth. The HBL also causes less extrusion and expansion in the molar area than does the rectangular wire. The HBL increases intercanine width, whereas the rectangular wire might not change it.
HBL of round wire seems an appropriate appliance and hence its clinical assessment is recommended.
使用传统方法(矩形丝)施加根扭矩会产生副作用,如反作用力和破坏性力、对相邻牙齿产生不利的扭矩、范围和持续时间有限的大力以及需要太多的疗程。我们引入了一种新方法(水平盒环[HBL]),旨在减少许多这些副作用;我们使用有限元分析测试了其效率和副作用。
为了永久上颌左中切牙,从 0.018 英寸圆形不锈钢弓丝制成等边三角形,边长为 7 毫米的 HBL。作为对照,使用 SS 矩形丝(19×25 英寸)。首先,进行了一项试点模拟,以使两种模型的扭矩标准化为 31.099 N·mm。应用相同力矩的矩形丝的扭转程度估计为 28.282°。主要研究评估了两种模型施加的 31.099 N·mm 扭矩对左中切牙的应力、牙齿移动(颊舌向、近远中向和外展或内收)以及尖牙间或磨牙间宽度的影响。
在标准化条件下,HBL 引起中切牙的腭根扭矩大于矩形丝。HBL 不会对相邻牙齿施加反向根扭矩,而矩形丝会导致相邻牙齿的反向根扭矩。HBL 还会导致磨牙区域的外展和扩展小于矩形丝。HBL 增加了尖牙间的宽度,而矩形丝可能不会改变它。
圆形丝的 HBL 似乎是一种合适的器具,因此建议对其进行临床评估。