Abstract

To understand the current status of major occupational hazards in 750 kV extra high voltage (EHV) substations. In July 2019, through investigating and detecting the sulfur hexafluoride, power frequency electric field and noise occupational hazards of 750 kV EHV substations in substation 1, substation 2, substation 3, substation 4, substation 5, substation 6 and substation 7, the exposure intensity of the sulfur hexafluoride, power frequency electric field and noise intensity that the operators are exposed to during the inspection process were analyzed. The qualified rate of 358 sulfur hexafluoride test results was 100.0% of the seven 750 kV EHV substations. The qualified rate of 8 h time-weighted average of the power frequency electric field of those 750 kV EHV substations contacted by operators was 100.0%. Among the 847 power frequency electric field detection points, the exceeding standard rate of power frequency electric field was 64.3%, and the differences in the power frequency electric field detection exceeding standard rates of different substations and inspection areas were statistically significant (χ=87.52, 50.86, <0.01) . The highest exceeding standard rate of power frequency electric field was the circuit breaker inspection area (94.4%, 34/36) . The noise intensity test results of the seven EHV substations were 41.1-79.7 dB (A) , and the qualified rate was 100.0%. The sulfur hexafluoride, power frequency electric field and noise that the operators contacted in 750 kV EHV substations meet the requirements of occupational exposure limits. The inspection areas of main transformers, capacitors, reactors, bus bars and switches have high power frequency electric field radiation, should be select equipment iand give priority to robot inspection, and reasonably adjust the inspection time to reduce the intensity level of substation operators' exposure to power frequency electric field.

摘要

了解750kV超高压(EHV)变电站主要职业危害的现状。2019年7月,通过对1号、2号、3号、4号、5号、6号和7号750kV EHV变电站的六氟化硫、工频电场和噪声职业危害进行调查检测,分析了操作人员在巡检过程中接触的六氟化硫、工频电场暴露强度和噪声强度。7座750kV EHV变电站的358份六氟化硫检测结果合格率为100.0%。操作人员接触的750kV EHV变电站工频电场8小时时间加权平均合格率为100.0%。在847个工频电场检测点中,工频电场超标率为64.3%,不同变电站和巡检区域的工频电场检测超标率差异有统计学意义(χ=87.52,50.86,<0.01)。工频电场超标率最高的是断路器巡检区域(94.4%,34/36)。7座EHV变电站的噪声强度检测结果为41.1-79.7dB(A),合格率为100.0%。750kV EHV变电站操作人员接触的六氟化硫、工频电场和噪声均符合职业接触限值要求。主变压器、电容器、电抗器、母线和开关的巡检区域工频电场辐射较高,应选用设备并优先采用机器人巡检,合理调整巡检时间,降低变电站操作人员接触工频电场的强度水平。

相似文献

1
[Investigation of occupational hazard of 750 kV extra high voltage substations].[750千伏特高压变电站职业危害调查]
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2021 Oct 20;39(10):763-765. doi: 10.3760/cma.j.cn121094-20201109-00621.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验