Institute of Medical Microbiology, Jena University Hospital, Friedrich Schiller University, Jena, Germany.
Division of Infection Control and Infectious Diseases, RWTH Aachen University Hospital, Aachen, Germany.
Eur J Clin Microbiol Infect Dis. 2022 Mar;41(3):489-494. doi: 10.1007/s10096-021-04383-3. Epub 2021 Nov 22.
The LAMP-based eazyplex® BloodScreen GN was evaluated for the detection of frequent Gram-negatives directly from positive blood culture (BC) bottles. A total of 449 BCs were analyzed. Sensitivities and specificities were 100% and 100% for Escherichia coli, 95.7% and 100% for Klebsiella pneumoniae, 100% and 100% for bla, 100% and 100% for Klebsiella oxytoca, 100% and 99% for Proteus mirabilis, and 100% and 99.8% for Pseudomonas aeruginosa, respectively. The time to result ranged from 8 to 16 min, plus about 6 min for sample preparation. The eazyplex® BloodScreen GN is a reliable molecular assay for rapid BC testing.
基于 LAMP 的 eazyplex® BloodScreen GN 用于直接从阳性血培养瓶中检测常见革兰氏阴性菌。共分析了 449 个血培养瓶。对于大肠杆菌,灵敏度和特异性均为 100%和 100%;对于肺炎克雷伯菌,灵敏度和特异性均为 95.7%和 100%;对于鲍曼不动杆菌,灵敏度和特异性均为 100%和 100%;对于奇异变形杆菌,灵敏度和特异性均为 100%和 99%;对于铜绿假单胞菌,灵敏度和特异性均为 100%和 99.8%。结果时间为 8 至 16 分钟,加上约 6 分钟的样本制备时间。eazyplex® BloodScreen GN 是一种用于快速血培养检测的可靠分子检测方法。