Suppr超能文献

使用 slim 纤毛电极在耳蜗植入后 24 小时内进行初始开启的效果。

Effect of initial switch-on within 24 hours of cochlear implantation using slim modiolar electrodes.

机构信息

Department of Otorhinolaryngology-Head and Neck Surgery, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea.

Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 300 Gumi-dong, Bundang-gu, Seongnam, 13620, Republic of Korea.

出版信息

Sci Rep. 2021 Nov 23;11(1):22809. doi: 10.1038/s41598-021-01862-7.

Abstract

Reducing electrode impedance is an important factor in improving the functional benefits of cochlear implants (CIs). The immediate effect of early switch-on within 24 h of surgery on impedance among CI recipients with various types of electrodes has been reported previously; however, the immediate change and the evolution of electrode impedances of slim modiolar electrodes after early switch-on within 24 h of implantation has not. Therefore, the focus of this retrospective cohort study of CI patients was to compare the effect of early switch-on (n = 36) and conventional switch-on (n = 72) 2-4 weeks post-operation on impedance. Compared with impedance measured intraoperatively, our results demonstrate a significant decrease in impedance from 11.5 to 8.9 kΩ (p < 0.001) at 2-4 weeks after implantation in the early switch-on group, which sharply contrasted with elevated impedance values for conventional switch-on 2-4 weeks after implantation (from 10.7 to 14.2 kΩ, p = 0.001). Notably, a comparatively lower impedance than the conventional switch-on protocol was observed for up to 2 months post-operation. Most importantly, a much earlier stabilization of impedance can be achieved with the early switch-on protocol coupled with the slim modiolar electrode array compared to the conventional switch-on protocol, offering the advantage of reducing the number of required mapping sessions in the early stages of rehabilitation.

摘要

降低电极阻抗是提高人工耳蜗(CI)功能效益的重要因素。先前已经报道了在手术后 24 小时内早期开机对不同类型电极的 CI 受者的阻抗的直接影响;然而,在植入后 24 小时内早期开机后 slim 纤毛电极的阻抗的直接变化和演变尚未可知。因此,本项针对 CI 患者的回顾性队列研究的重点是比较早期开机(n=36)和传统开机(n=72)对术后 2-4 周阻抗的影响。与术中测量的阻抗相比,我们的结果表明,早期开机组在植入后 2-4 周的阻抗从 11.5 降至 8.9 kΩ(p<0.001),这与传统开机组在植入后 2-4 周阻抗值升高形成鲜明对比(从 10.7 升至 14.2 kΩ,p=0.001)。值得注意的是,与传统开机方案相比,手术后长达 2 个月观察到的阻抗值相对较低。最重要的是,与传统开机方案相比,早期开机方案与 slim 纤毛电极阵列结合使用可以实现阻抗更快的稳定,从而减少康复早期所需的映射会话次数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4972/8611070/38c079a04dda/41598_2021_1862_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验