Suppr超能文献

骨水泥型钴铬合金与氮化钛铌活动平台单髁膝关节置换术在临床及影像学上无差异。

No Clinical or Radiographic Differences Between Cemented Cobalt-Chromium and Titanium-Niobium Nitride Mobile-Bearing Unicompartmental Knee Arthroplasty.

作者信息

D'Ambrosi Riccardo, Loucas Rafael, Loucas Marios, Giorgino Riccardo, Ursino Nicola, Peretti Giuseppe Maria

机构信息

IRCCS Istituto Ortopedico Galeazzi, Via Galeazzi 4, 20161 Milan, Italy.

Department of Orthopedics, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland.

出版信息

Indian J Orthop. 2021 Aug 15;55(5):1195-1201. doi: 10.1007/s43465-021-00486-3. eCollection 2021 Oct.

Abstract

PURPOSE

This study aimed to compare the clinical and radiographic outcomes of patients with positive patch tests undergoing a medial mobile-bearing titanium-niobium nitride (TiNbN) unicompartmental knee arthroplasty (UKA) to patients undergoing standard UKA (cobalt-chromium [CoCr] implants).

METHODS

Two successive groups of patients, amounting to a total of 246 individuals, who received Oxford (Zimmer-Biomet, Warsaw, Indiana, USA) UKA were included. The first group was composed of a series of 203 consecutive standard CoCr UKAs (Standard Group), while the second group comprised 43 consecutive hypoallergenic TiNbN UKAs (HA group). The patients of the second group had a positive epicutaneous patch test result for metals. Each patient was evaluated using the Oxford Knee Score (OKS) and Knee Society Score (KSS) a day prior to the surgery ( ) and at two consecutive follow-ups, namely (minimum follow-up of 12 months) and (minimum follow-up of 34 months). Radiographic measurements were performed at the final follow-up ( ).

RESULTS

No statistical differences were noted between the two groups regarding demographic data ( > 0.05). No clinical or radiographic differences were found between the HA and standard groups at any follow-up ( > 0.05). A statistically significant improvement was found at any follow-up for both OKS and KSS ( < 0.05).

CONCLUSIONS

No clinical or radiographic differences between the hypoallergenic and standard cobalt-chromium groups at any follow-up were found, with a clinically significant improvement being experienced by both groups during the entire follow-up.

LEVEL OF EVIDENCE

Level II-comparative prospective study.

SUPPLEMENTARY INFORMATION

The online version contains supplementary material available at 10.1007/s43465-021-00486-3.

摘要

目的

本研究旨在比较接受内侧活动平台氮化钛铌(TiNbN)单髁膝关节置换术(UKA)的斑贴试验阳性患者与接受标准UKA(钴铬[CoCr]植入物)患者的临床和影像学结果。

方法

纳入两组连续的患者,共246例,均接受牛津(Zimmer-Biomet,美国印第安纳州华沙)UKA。第一组由203例连续的标准CoCr UKA组成(标准组),而第二组包括43例连续的低过敏性TiNbN UKA(HA组)。第二组患者的皮肤斑贴试验金属结果为阳性。在手术前一天( )以及连续两次随访时,即 (最短随访12个月)和 (最短随访34个月),使用牛津膝关节评分(OKS)和膝关节协会评分(KSS)对每位患者进行评估。在最终随访时( )进行影像学测量。

结果

两组在人口统计学数据方面无统计学差异( > 0.05)。在任何随访中,HA组和标准组之间均未发现临床或影像学差异( > 0.05)。在任何随访中,OKS和KSS均有统计学显著改善( < 0.05)。

结论

在任何随访中,低过敏性组和标准钴铬组之间均未发现临床或影像学差异,两组在整个随访期间均有临床显著改善。

证据水平

II级——比较性前瞻性研究。

补充信息

在线版本包含可在10.1007/s43465-021-00486-3获取的补充材料。