Suppr超能文献

用于经皮脊髓刺激自动校准以促进临床应用的算法。

Algorithms for Automated Calibration of Transcutaneous Spinal Cord Stimulation to Facilitate Clinical Applications.

作者信息

Salchow-Hömmen Christina, Schauer Thomas, Müller Philipp, Kühn Andrea A, Hofstoetter Ursula S, Wenger Nikolaus

机构信息

Department of Neurology, Charité-Universitätsmedizin Berlin, 10117 Berlin, Germany.

Control Systems Group, Technische Universität Berlin, 10587 Berlin, Germany.

出版信息

J Clin Med. 2021 Nov 22;10(22):5464. doi: 10.3390/jcm10225464.

Abstract

Transcutaneous spinal cord stimulation (tSCS) is a promising intervention that can benefit spasticity control and augment voluntary movement in spinal cord injury (SCI) and multiple sclerosis. Current applications require expert knowledge and rely on the thorough visual analysis of electromyographic (EMG) responses from lower-limb muscles to optimize attainable treatment effects. Here, we devised an automated tSCS setup by combining an electrode array placed over low-thoracic to mid-lumbar vertebrae, synchronized EMG recordings, and a self-operating stimulation protocol to systematically test various stimulation sites and amplitudes. A built-in calibration procedure classifies the evoked responses as reflexes or direct motor responses and identifies stimulation thresholds as recommendations for tSCS therapy. We tested our setup in 15 individuals (five neurologically intact, five SCI, and five Parkinson's disease) and validated the results against blinded ratings from two clinical experts. Congruent results were obtained in 13 cases for electrode positions and in eight for tSCS amplitudes, with deviations of a maximum of one position and 5 to 10 mA in amplitude in the remaining cases. Despite these minor deviations, the calibration found clinically suitable tSCS settings in 13 individuals. In the remaining two cases, the automatic setup and both experts agreed that no reflex responses could be detected. The presented technological developments may facilitate the dissemination of tSCS into non-academic environments and broaden its use for diagnostic and therapeutic purposes.

摘要

经皮脊髓刺激(tSCS)是一种很有前景的干预措施,可有益于脊髓损伤(SCI)和多发性硬化症患者的痉挛控制并增强自主运动。目前的应用需要专业知识,且依赖于对下肢肌肉肌电图(EMG)反应进行全面的视觉分析,以优化可达到的治疗效果。在此,我们通过结合放置在低胸段至中腰段椎骨上的电极阵列、同步EMG记录以及自动操作的刺激方案,设计了一种自动化tSCS装置,以系统地测试各种刺激部位和幅度。一个内置的校准程序将诱发反应分类为反射或直接运动反应,并确定刺激阈值,作为tSCS治疗的建议。我们在15名个体(5名神经功能正常者、5名SCI患者和5名帕金森病患者)中测试了我们的装置,并根据两名临床专家的盲法评分对结果进行了验证。在13例电极位置和8例tSCS幅度的情况下获得了一致的结果,其余情况下最大偏差为一个位置,幅度偏差为5至10 mA。尽管存在这些小偏差,但校准在13名个体中找到了临床上合适的tSCS设置。在其余两例中,自动装置和两位专家都一致认为未检测到反射反应。所展示的技术进展可能有助于将tSCS推广到非学术环境中,并扩大其在诊断和治疗方面的应用。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f8be/8623351/71b8d371f00e/jcm-10-05464-g0A1.jpg

相似文献

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验