Telemedicine can be used to conduct ophthalmological assessment of patients, facilitating patient access to specialist care. Since the teleophthalmology models require data collection support from other health professionals, the purpose of our study was to assess agreement between the nursing technician and the ophthalmologist in acquisition of health parameters that can be used for remote analysis as part of a telemedicine strategy. A cross-sectional study was conducted with 140 patients referred to an ophthalmological telediagnosis center by primary healthcare doctors. The health parameters evaluated were visual acuity (VA), objective ophthalmic measures acquired by autorefraction, keratometry, and intraocular pressure (IOP). Bland-Altman plots were used to analyze agreement between the nursing technician and the ophthalmologist. The Bland-Altman analysis showed a mean bias equal to zero for the VA measurements [95%-LoA: -0.25-0.25], 0.01 [95%-LoA: -0.86-0.88] for spherical equivalent (M), -0.08 [95%-LoA: -1.1-0.95] for keratometry (K) and -0.23 [95%-LoA: -4.4-4.00] for IOP. The measures had a high linear correlation (R [95%CI]: 0.87 [0.82-0.91]; 0.97 [0.96-0.98]; 0.96 [0.95-0.97] and 0.88 [0.84-0.91] respectively). The results observed demonstrate that remote ophthalmological data collection by adequately trained health professionals is viable. This confirms the utility and safety of these solutions for scenarios in which access to ophthalmologists is limited.
远程医疗可用于对患者进行眼科评估,使患者能够获得专家护理。由于远程眼科模型需要其他卫生专业人员提供数据收集支持,因此我们的研究目的是评估护理技术员与眼科医生在获取可用于远程分析的健康参数方面的一致性,这些参数是远程医疗策略的一部分。这是一项横断面研究,共纳入了 140 名由初级保健医生转诊至眼科远程诊断中心的患者。评估的健康参数包括视力(VA)、自动折射获得的客观眼科测量值、角膜曲率和眼内压(IOP)。使用 Bland-Altman 图分析护理技术员和眼科医生之间的一致性。Bland-Altman 分析显示,VA 测量的平均偏差为零[95%-LoA:-0.25-0.25],等效球镜度(M)的偏差为 0.01[95%-LoA:-0.86-0.88],角膜曲率(K)的偏差为-0.08[95%-LoA:-1.1-0.95],IOP 的偏差为-0.23[95%-LoA:-4.4-4.00]。这些测量值具有高度线性相关性(R [95%CI]:0.87[0.82-0.91];0.97[0.96-0.98];0.96[0.95-0.97]和 0.88[0.84-0.91])。观察到的结果表明,由经过适当培训的卫生专业人员进行远程眼科数据收集是可行的。这证实了这些解决方案在眼科医生资源有限的情况下具有实用性和安全性。