Blue Pearl Veterinary Partners, Tampa, FL.
Mars Veterinary Health, Vancouver, WA.
Am J Vet Res. 2021 Dec 9;83(2):140-146. doi: 10.2460/ajvr.21.04.0060.
To calculate the necessary pseudophakic intraocular lens (IOL) power to approximate emmetropia in adult tigers.
17 clinically normal adult tigers.
33 eyes of 17 clinically normal adult tigers underwent routine ophthalmic examination and B-scan ultrasonography while anesthetized for unrelated procedures. Specific ultrasound data (globe measurements and corneal curvature) and estimated postoperative IOL positions were utilized to calculate predicted IOL power by use of Retzlaff and Binkhorst theoretical formulas. Applanation tonometry and refraction were also performed.
Mean ± SD axial globe length was 29.36 ± 0.82 mm, preoperative anterior chamber depth was 7.00 ± 0.74 mm, and crystalline lens thickness was 8.72 ± 0.56 mm. Mean net refractive error (n = 33 eyes) was +0.27 ± 0.30 diopters (D). By use of the Retzlaff formula, mean predicted IOL power for the postoperative anterior chamber depth (PACD), PACD - 2 mm, and PACD + 2 mm was 43.72 ± 4.84 D, 37.62 ± 4.19 D, and 51.57 ± 5.72 D, respectively. By use of the Binkhorst equation, these values were 45.11 ± 4.91 D, 38.84 ± 4.25 D, and 53.18 ± 5.81 D, respectively. Mean intraocular pressure for all eyes was 14.7 ± 2.69 mm Hg.
The calculated tiger IOL was lower than reported values for adult domestic felids. Further studies evaluating actual PACD and pseudophakic refraction would help determine the appropriate IOL power to achieve emmetropia in this species.
计算接近成年老虎正视所需的人工晶状体(IOL)度数。
17 只临床正常成年老虎。
在进行无关程序麻醉下,对 17 只临床正常成年老虎的 33 只眼进行了常规眼科检查和 B 型超声检查。利用特定的超声数据(眼球测量值和角膜曲率)和估计的术后 IOL 位置,通过 Retzlaff 和 Binkhorst 理论公式计算预测 IOL 度数。还进行了压平眼压测量和验光。
平均±标准差眼轴长度为 29.36±0.82mm,术前前房深度为 7.00±0.74mm,晶状体厚度为 8.72±0.56mm。平均净屈光不正(n=33 只眼)为+0.27±0.30 屈光度(D)。使用 Retzlaff 公式,术后前房深度(PACD)、PACD-2mm 和 PACD+2mm 的平均预测 IOL 度数分别为 43.72±4.84D、37.62±4.19D 和 51.57±5.72D。使用 Binkhorst 方程,这些值分别为 45.11±4.91D、38.84±4.25D 和 53.18±5.81D。所有眼的平均眼压为 14.7±2.69mmHg。
计算出的老虎 IOL 低于已报道的成年家养猫科动物的 IOL 度数。进一步研究评估实际的 PACD 和人工晶状体后的屈光状态,将有助于确定实现该物种正视所需的适当 IOL 度数。