使用 ActiGraph GT3X+ 和 Axivity AX3 加速度计比较得出的结果来客观测量成年人 24 小时运动行为:一项横断面研究。

Comparison of Outcomes Derived from the ActiGraph GT3X+ and the Axivity AX3 Accelerometer to Objectively Measure 24-Hour Movement Behaviors in Adults: A Cross-Sectional Study.

机构信息

Department of Rehabilitation Sciences, Faculty of Medicine and Health Sciences, Ghent University, Corneel Heymanslaan 10, 9000 Ghent, Belgium.

Research Foundation Flanders, Egmontstraat 5, 1000 Brussels, Belgium.

出版信息

Int J Environ Res Public Health. 2021 Dec 27;19(1):271. doi: 10.3390/ijerph19010271.

Abstract

The aim of this cross-sectional study is to investigate convergent validity of outcomes derived from the ActiGraph GT3X and Axivity accelerometer and to investigate feasibility and acceptability of using outcomes derived from these devices to measure 24-h movement behaviors (i.e., sleep, sedentary behavior, and physical activity) in adults during free-living conditions. Twenty-four adults (33.3% male; 39.79 ± 13.09 years old) simultaneously wore a hip-mounted ActiGraph and thigh-mounted Axivity during 48 consecutive hours. The ActiGraph was switched from hip to wrist during the night. To assess convergent validity between the two devices, Paired sample -tests, linear regressions, Bland-Altman plots and statistic were conducted. Feasibility and acceptability of the devices was self-reported on a five-point scale. Daily time spent in 24-h movement behaviors differed between both devices. Except for sleep, the mean differences in daily time spent in the behaviors were clinically relevant and the limits of agreement were wide. For all 24-h movement behaviors, except for sleep and vigorous physical activity, proportional errors were observed. κ statistic showed substantial agreement for total physical activity and outstanding agreement for sedentary behavior and sleep. Adults perceived the Axivity as more practical than the ActiGraph to wear it for more than two days whereas the feasibility to wear it for two days was comparable. Depending on the measure, the observed biases were clinically relevant, proportional to the size of the measure and/or erratically variable. When taking into account the data processing approaches applied in this study, the ActiGraph and the Axivity cannot be used interchangeably to measure 24-h movement behaviors since the bias between both devices is clinically relevant and unpredictable.

摘要

本横断面研究的目的是调查 ActiGraph GT3X 和 Axivity 加速度计得出的结果的收敛效度,并调查使用这些设备得出的结果来测量成年人在自由生活条件下 24 小时运动行为(即睡眠、久坐行为和身体活动)的可行性和可接受性。24 名成年人(33.3%为男性;39.79±13.09 岁)同时在 48 小时内佩戴髋部安装的 ActiGraph 和大腿安装的 Axivity。夜间将 ActiGraph 从髋部切换到手部。为了评估两种设备之间的收敛效度,进行了配对样本检验、线性回归、Bland-Altman 图和 κ 统计。使用五分制自我报告设备的可行性和可接受性。两种设备记录的 24 小时运动行为的日时间存在差异。除了睡眠外,行为的日时间差异具有临床意义,且一致性界限较宽。对于所有 24 小时运动行为,除了睡眠和剧烈身体活动外,还观察到比例误差。κ 统计显示,对于总身体活动和久坐行为及睡眠,具有显著一致性。成年人认为 Axivity 比 ActiGraph 更实用,可佩戴两天以上,而佩戴两天的可行性相当。根据测量指标,观察到的偏差具有临床意义,与测量指标的大小成比例,并且/或者不稳定。考虑到本研究中应用的数据处理方法,ActiGraph 和 Axivity 不能互换使用来测量 24 小时运动行为,因为两种设备之间的偏差具有临床意义且不可预测。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9761/8750776/bdf6c5c950dc/ijerph-19-00271-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验