Suppr超能文献

使用临床适用的测量工具评估单侧髋关节炎老年患者髋关节位置觉测试的可靠性。

Reliability of hip joint position sense tests using a clinically applicable measurement tool in elderly participants with unilateral hip osteoarthritis.

机构信息

Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.

College of Health Sciences, Gulf Medical University, Ajman, United Arab Emirates.

出版信息

Sci Rep. 2022 Jan 10;12(1):376. doi: 10.1038/s41598-021-04288-3.

Abstract

Hip joint proprioception is vital in maintaining posture and stability in elderly individuals. Examining hip joint position sense (JPS) using reliable tools is important in contemporary clinical practice. The objective of this study is to evaluate the intra-rater and inter-rater reliability of hip JPS tests using a clinically applicable measurement tool in elderly individuals with unilateral hip osteoarthritis (OA). Sixty-two individuals (mean age = 67.5 years) diagnosed with unilateral hip OA participated in this study. The JPS tests were evaluated using a digital inclinometer in hip flexion and abduction directions. The absolute difference between target and reproduced angle (repositioning error) in degrees was taken to measure JPS accuracy. The intraclass correlation coefficient (ICC (2.k), was used to assess the reliability. The Intra rater-reliability for hip JPS tests showed very good agreement in the lying position (hip flexion-ICC = 0.88-0.92; standard error of measurement (SEM) = 0.06-0.07, hip abduction-ICC = 0.89-0.91; SEM = 0.06-0.07) and good agreement in the standing position (hip flexion-ICC = 0.69-0.72; SEM = 0.07, hip abduction-ICC = 0.66-0.69; SEM = 0.06-0.08). Likewise, inter-rater reliability for hip JPS tests demonstrated very good agreement in the lying position (hip flexion-ICC = 0.87-0.89; SEM = 0.06-0.07, hip abduction-ICC = 0.87-0.91; SEM = 0.07) and good agreement in the standing position (hip flexion-ICC = 0.64-0.66; SEM = 0.08, hip abduction-ICC = 0.60-0.72; SEM = 0.06-0.09). The results support the use of hip JPS tests in clinical practice and should be incorporated in assessing and managing elderly participants with hip OA.

摘要

髋关节本体感觉对于维持老年人的姿势和稳定性至关重要。使用可靠的工具检查髋关节位置感(JPS)在当代临床实践中非常重要。本研究的目的是评估使用临床适用的测量工具在单侧髋关节骨关节炎(OA)的老年个体中髋关节 JPS 测试的内部和外部可靠性。共有 62 名(平均年龄 67.5 岁)被诊断为单侧髋关节 OA 的个体参加了这项研究。使用数字测斜仪在髋关节屈曲和外展方向评估 JPS 测试。目标角度和再现角度之间的绝对差异(重新定位误差)以度为单位测量 JPS 准确性。使用组内相关系数(ICC(2.k)评估可靠性。髋关节 JPS 测试的内部可靠性在卧位时显示出非常好的一致性(髋关节屈曲-ICC=0.88-0.92;测量误差(SEM)=0.06-0.07,髋关节外展-ICC=0.89-0.91;SEM=0.06-0.07),在站立位时显示出良好的一致性(髋关节屈曲-ICC=0.69-0.72;SEM=0.07,髋关节外展-ICC=0.66-0.69;SEM=0.06-0.08)。同样,髋关节 JPS 测试的外部可靠性在卧位时显示出非常好的一致性(髋关节屈曲-ICC=0.87-0.89;SEM=0.06-0.07,髋关节外展-ICC=0.87-0.91;SEM=0.07),在站立位时显示出良好的一致性(髋关节屈曲-ICC=0.64-0.66;SEM=0.08,髋关节外展-ICC=0.60-0.72;SEM=0.06-0.09)。研究结果支持在临床实践中使用髋关节 JPS 测试,并应纳入评估和管理患有髋关节 OA 的老年参与者。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a390/8748869/f201e2b46717/41598_2021_4288_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验