Angle Orthod. 2022 May 1;92(3):358-363. doi: 10.2319/040921-290.1.
To compare three-dimensional facial scans obtained by stereophotogrammetry with two different applications for smartphone supporting the TrueDepth system, a structured light technology.
Facial scans of 40 different subjects were acquired with three different systems. The 3dMDtrio Stereophotogrammetry System (3dMD, Atlanta, Ga) was compared with a smartphone (iPhone Xs; Apple, Cupertino, Calif) equipped with the Bellus3D Face Application (version 1.6.11; Bellus3D Inc, Campbell, Calif) or Capture (version 1.2.5; Standard Cyborg Inc, San Francisco, Calif). Times of image acquisition and elaboration were recorded. The surface-to-surface deviation and the distance between 18 landmarks from 3dMD reference images to those acquired with Bellus3D or Capture were measured.
Capturing and processing times with the smartphone applications were considerably longer than with the 3dMD system. The surface-to-surface deviation analysis between the Bellus3D and 3dMD showed an overlap percentage of 80.01% ± 5.92% and 56.62% ± 7.65% within the ranges of 1 mm and 0.5 mm discrepancy, respectively. Images from Capture showed an overlap percentage of 81.40% ± 9.59% and 56.45% ± 11.62% within the ranges of 1 mm and 0.5 mm, respectively.
The face image acquisition with the 3dMD device is fast and accurate, but bulky and expensive. The new smartphone applications combined with the TrueDepth sensors show promising results. They need more accuracy from the operator and more compliance from the patient because of the increased acquisition time. Their greatest advantages are related to cost and portability.
比较三种不同的智能手机立体摄影测量系统,这些系统都支持 TrueDepth 系统,即结构光技术,获得的三维面部扫描结果。
使用三种不同的系统对 40 名不同受试者的面部扫描进行采集。将 3dMDtrio 立体摄影测量系统(3dMD,佐治亚州亚特兰大)与配备 Bellus3D Face 应用程序(版本 1.6.11;Bellus3D Inc,加利福尼亚州坎贝尔)或 Capture 应用程序(版本 1.2.5;Standard Cyborg Inc,旧金山,加利福尼亚州)的智能手机(iPhone Xs;Apple,加利福尼亚州库比蒂诺)进行比较。记录图像采集和处理的时间。测量 3dMD 参考图像与 Bellus3D 或 Capture 采集图像之间 18 个标志点的表面到表面偏差和距离。
智能手机应用程序的采集和处理时间明显长于 3dMD 系统。Bellus3D 与 3dMD 之间的表面到表面偏差分析显示,在 1mm 和 0.5mm 差异范围内,重叠百分比分别为 80.01%±5.92%和 56.62%±7.65%。Capture 的图像显示,在 1mm 和 0.5mm 差异范围内,重叠百分比分别为 81.40%±9.59%和 56.45%±11.62%。
3dMD 设备的面部图像采集快速准确,但设备庞大且昂贵。新的智能手机应用程序与 TrueDepth 传感器相结合,结果令人鼓舞。由于采集时间的增加,它们需要操作人员更高的准确性和患者更高的依从性。它们最大的优势与成本和便携性有关。