Sinha Sonal, Singh Konark, Singh Anju, Priya Swati, Kumar Avanindra, Kawle Sahil
Department of Conservative Dentistry and Endodontics, Dr. B. R. Ambedkar Institute of Dental Sciences and Hospital, Bihar, India.
Department of Conservative Dentistry and Endodontics, Patna Dental College and Hospital, Bihar, India.
J Pharm Bioallied Sci. 2021 Nov;13(Suppl 2):S1398-S1401. doi: 10.4103/jpbs.jpbs_225_21. Epub 2021 Nov 10.
Prevention of the debris from extruding to the periapical region is an important aspect to be taken care of as its extrusion can result in pain, periapical inflammation, and delayed healing owing to the presence of highly infective components in the debris.
The present trial was aimed to compare and assess the amount of debris extruded apically using the single-file reciprocating system - WaveOne GOLD and single file rotary system - OneShape in root canal preparations .
Thirty mandibular premolars were divided into two groups (15 samples each) prepared with a single-file reciprocating system - WaveOne GOLD and single-file rotary system - OneShape. Debris extruded was collected and then stored in an incubator. The final weight was calculated after obtaining the mean of three consecutive weights obtained for each tooth. The data were compared using the ANOVA and Turkey's post hoc analysis.
Debris extrusions were recorded in both groups and analysis revealed statistical differences in weight before and after the instrumentation procedures in both groups. When compared, reciprocating single file - WaveOne GOLD extruded more debris than rotary single file system - OneShape with a < 0.001.
The rotary instrumentation systems extrude lesser debris apically than the reciprocating instrumentation system. The difference found was statistically significant.
防止碎屑挤压到根尖周区域是一个需要关注的重要方面,因为碎屑的挤压会由于其高感染性成分的存在而导致疼痛、根尖周炎和愈合延迟。
本试验旨在比较和评估在根管预备中使用单根往复系统WaveOne GOLD和单根旋转系统OneShape时根尖挤压出的碎屑量。
30颗下颌前磨牙分为两组(每组15个样本),分别用单根往复系统WaveOne GOLD和单根旋转系统OneShape进行预备。收集挤压出的碎屑,然后储存在培养箱中。在获得每颗牙齿连续三次称重的平均值后计算最终重量。使用方差分析和土耳其事后分析对数据进行比较。
两组均记录到碎屑挤压,分析显示两组在器械操作前后的重量存在统计学差异。相比之下,往复单根WaveOne GOLD比旋转单根系统OneShape挤压出更多碎屑,P<0.001。
旋转器械系统根尖挤压出的碎屑比往复器械系统少。发现的差异具有统计学意义。