Abstract

Impermeability is a feature of fully encapsulated chemical protective ensembles (FCPE), which can affect people's sweat and affect their clothing's thermal-wet comfort. This study investigated the dynamics of upper-body sweat distribution in young males wearing FCPE and explored variations in sweat rate intra-region and inter-time for 10 young and healthy male college students. The study was carried in a climatic chamber (environment temperature 35 °C, relative humidity 60%) with participants exercising on a treadmill at 4 km/h, 5%. Sweat was collected using a 35-pad set of absorbent pads that were changed every 5 min during the course of the experiment. A total of 7-pad sets were collected with an average sweat rate of 389, 631, 920, 1137, 1100, 1211, and 1105 g m h, respectively. The medial upper back, lateral lower back, medial upper chest, medial mid-back, and lateral top back had the highest sweat rates, with average values of 1406, 1278, 1198, 1181 and 1139 g m h, respectively. The waist (with average values of 557, 370, 596, and 332 g m h, respectively) and bottom zones (373, 398, 661, and 849 g m h, respectively) had the lowest sweat rates. The above data showed that the role of FCPE in promoting body perspiration. The upper body may be split into three zones of sweat rates based on the distribution result allowing for the design of more comfortable clothing. The study includes the fundamental physiological data as well as the design recommendations for advanced personal protective equipment.

摘要

不透气是全封闭化学防护服(FCPE)的一个特点,它会影响人体出汗,影响服装的热湿舒适感。本研究调查了穿着 FCPE 的年轻男性上半身汗液分布的动态变化,并探索了 10 名年轻健康男性大学生在同一区域和不同时间的出汗率变化。研究在气候室内进行(环境温度 35°C,相对湿度 60%),参与者在跑步机上以 4km/h、5%的速度运动。使用一套 35 个吸收垫的装置收集汗水,在实验过程中每 5 分钟更换一次。共收集了 7 套垫子,平均出汗率分别为 389、631、920、1137、1100、1211 和 1105g·m-2·h-1。中背部、下背部、胸部、中背部和上背部的内侧有最高的出汗率,平均值分别为 1406、1278、1198、1181 和 1139g·m-2·h-1。腰部(平均值分别为 557、370、596 和 332g·m-2·h-1)和底部区域(平均值分别为 373、398、661 和 849g·m-2·h-1)的出汗率最低。上述数据表明,FCPE 在促进身体出汗方面发挥了作用。根据分布结果,上半身可能分为三个出汗率区域,这为设计更舒适的服装提供了依据。本研究提供了基础生理数据以及先进个人防护装备的设计建议。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/676c/8770470/d4297a134936/41598_2022_4974_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验