Suppr超能文献

采用内置固定板增强犬腓肠肌腱初级三圈滑液囊修复术的体外生物力学特征及对间隙形成的影响。

Ex vivo biomechanical characteristics and effects on gap formation of using an internal fixation plate to augment primary three-loop pulley repair of canine gastrocnemius tendons.

机构信息

Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC.

Department of Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, IN.

出版信息

Am J Vet Res. 2022 Jan 28;83(4):305-311. doi: 10.2460/ajvr.21.07.0088.

Abstract

OBJECTIVE

To evaluate the effects of using an internal fixation plate to augment primary 3-loop pulley (3LP) repair of canine gastrocnemius tendons (GTs).

SAMPLE

48 cadaveric GTs from 24 adult dogs.

PROCEDURES

GTs were dissected free from other tissues, transected, and randomly assigned to 4 groups (n = 12/group). GTs were repaired with 2-0 polypropylene with a 3LP repair alone or a 3LP repair augmented with a 3-hole veterinary cuttable plate (3VCP), a 5-hole veterinary cuttable plate (5VCP), or a 7-hole veterinary cuttable plate (7VC P). Biomechanical loads, construct stiffness, gap formation, and failure modes were compared between groups.

RESULTS

Yield, peak, and failure loads were all significantly increased for the 5VCP and 7VCP groups, compared with the 3LP alone group. Increasing plate length from 3VCP to 5VCP and from 3VCP to 7VCP increased yield, peak, and failure loads. No differences were found between the 3LP and 3VCP groups with regard to yield and peak loads, but failure load was increased in the 3VCP group. Loads to create 1-mm and 3-mm gaps were significantly greater for the 5VCP and 7VCP groups, compared with the 3LP alone and 3VCP groups. Mode of plate attachment failure differed among groups.

CLINICAL RELEVANCE

Tendon plate augmentation may be a viable surgical option to increase the strength of the tenorrhaphy in dogs. However, in vivo studies evaluating the effects of plate augmentation on the tendon blood supply and progression of healing are needed prior to clinical application.

摘要

目的

评估使用内置固定板增强犬腓肠肌腱(GTs)的原发性 3 圈滑车(3LP)修复的效果。

样本

24 只成年犬的 48 个 GT 标本。

程序

从其他组织中解剖 GT,横断并随机分配到 4 组(每组 12 个标本)。GT 用 2-0 聚丙烯单 3LP 修复或 3LP 修复增强 3 孔兽医可切割板(3VCP)、5 孔兽医可切割板(5VCP)或 7 孔兽医可切割板(7VCP)修复。比较各组间的生物力学载荷、结构刚度、间隙形成和失效模式。

结果

与 3LP 单独组相比,5VCP 和 7VCP 组的屈服、峰值和失效载荷均显著增加。将板长度从 3VCP 增加到 5VCP 和 3VCP 增加到 7VCP 增加了屈服、峰值和失效载荷。3LP 和 3VCP 组之间在屈服和峰值载荷方面没有差异,但 3VCP 组的失效载荷增加。创建 1mm 和 3mm 间隙的载荷在 5VCP 和 7VCP 组中明显大于 3LP 单独和 3VCP 组。各组中板附着失效的模式不同。

临床相关性

肌腱板增强可能是增加犬肌腱修复强度的可行手术选择。然而,在临床应用之前,需要进行体内研究评估板增强对肌腱血液供应和愈合进展的影响。