Suppr超能文献

丙烯酸酯疏水性人工晶状体的几何形状以及根据压缩和不同囊袋直径导致的襻-囊袋关系变化:一项使用计算机断层扫描的实验研究

Geometry of Acrylic, Hydrophobic IOLs and Changes in Haptic-Capsular Bag Relationship According to Compression and Different Well Diameters: A Bench Study Using Computed Tomography.

作者信息

Borkenstein Andreas F, Borkenstein Eva-Maria

机构信息

GrazBorkenstein & Borkenstein, Private Practice at Privatklinik Kreuzschwestern, Kreuzgasse 35, 8010, Graz, Austria.

出版信息

Ophthalmol Ther. 2022 Apr;11(2):711-727. doi: 10.1007/s40123-022-00469-z. Epub 2022 Feb 5.

Abstract

INTRODUCTION

Characteristics of the haptics and optic-haptic junction (OHJ) of an intraocular lens (IOL) affect IOL position in the capsular bag, positional stability, and the development of posterior capsule opacification. Therefore, the haptics and OHJ have a role in determining initial and long-term visual outcomes after cataract surgery. Understanding differences in the haptics and OHJ of available IOLs and in the relationships between the haptics of each IOL and the capsular bag across a range of capsular bag sizes might inform selection of an IOL model for individuals.

PURPOSE

To evaluate the geometry of five currently marketed, commonly used one-piece hydrophobic acrylic monofocal IOLs and changes in haptic-capsular bag relationships according to capsular bag size using a range of compression well diameters.

METHODS

AcrySof SN60WF, CT LUCIA 621PY, enVista MX60, TECNIS ZCB00, and Vivinex XY1 IOLs were scanned with computed tomography (CT) in a dry, uncompressed state for quantitative analyses of haptic and OHJ dimensions and qualitative assessment of geometry. CT scanning was done after IOL placement into a series of compression wells (11.5, 11.0, 10.0, and 9.0 mm) for analyses of haptic angle of contact (AoC) and capsular bag contact (CBC). IOL axial alignment and haptic-capsular bag relationships were assessed on side-view and 3-dimensional top-view images, respectively.

RESULTS

The qualitative and quantitative evaluations highlighted differences in haptic and OHJ geometry and dimensions across the five IOLs. All haptic dimensions (length, thickness, surface area, volume) and all OHJ dimensions (surface area and volume) were greatest for the CT LUCIA 621PY IOL. Compared to the IOL that had the smallest measurement for each parameter, the value for the CT LUCIA 621PY IOL was 31-91% larger. The lens with the largest OHJ surface area and volume showed values that were 500% and 240% greater than the corresponding values for the lens with the smallest OHJ surface area and OHJ volume. The AoC and CBC values decreased with increasing well size for all IOLs. The CT LUCIA 621PY had the greatest AoC and CBC values for all well sizes and the smallest percentage change in AoC and CBC comparing the values from the 9.0 mm and 11.5 mm wells.

CONCLUSION

The in vitro evaluations in this study highlight differences in the haptic and OHJ geometric characteristics of the five IOLs studied. The collected evidence refutes opinions that all hydrophobic acrylic one-piece IOLs are the same and supports the idea that individual IOLs can have relative advantages and disadvantages that depend on the individual case. We believe the knowledge of geometry is necessary for the surgeon to have the opportunity to select the best "customized" option in the individual case as a result of anatomical conditions and secondary diagnoses. Our bench study shows how big the differences are in currently available monofocal hydrophobic acrylic lenses.

摘要

引言

人工晶状体(IOL)的触觉部及视触觉交界处(OHJ)的特征会影响IOL在囊袋内的位置、位置稳定性以及后囊膜混浊的发展。因此,触觉部及OHJ在决定白内障手术后的初始和长期视觉效果方面发挥着作用。了解现有IOL的触觉部及OHJ的差异,以及在一系列囊袋大小范围内每个IOL的触觉部与囊袋之间的关系,可能有助于为个体选择IOL型号。

目的

使用一系列不同直径的压缩孔,评估五种目前市场上常用的一体式疏水丙烯酸单焦点IOL的几何形状,以及触觉部与囊袋的关系随囊袋大小的变化。

方法

对AcrySof SN60WF、CT LUCIA 621PY、enVista MX60、TECNIS ZCB00和Vivinex XY1 IOL在干燥、未压缩状态下进行计算机断层扫描(CT),以对触觉部和OHJ尺寸进行定量分析,并对几何形状进行定性评估。将IOL放入一系列压缩孔(11.5、11.0、10.0和9.0毫米)后进行CT扫描,以分析触觉接触角(AoC)和囊袋接触(CBC)。分别在侧视图和三维顶视图图像上评估IOL的轴向对齐和触觉部与囊袋的关系。

结果

定性和定量评估突出了五种IOL在触觉部和OHJ几何形状及尺寸上的差异。CT LUCIA 621PY IOL的所有触觉部尺寸(长度、厚度、表面积、体积)和所有OHJ尺寸(表面积和体积)最大。与每个参数测量值最小的IOL相比,CT LUCIA 621PY IOL的值大31%-91%。OHJ表面积和体积最大的晶状体的值分别比OHJ表面积和体积最小的晶状体的相应值大500%和240%。所有IOL的AoC和CBC值均随孔尺寸的增加而降低。对于所有孔尺寸,CT LUCIA 621PY的AoC和CBC值最大,并且比较9.0毫米和11.5毫米孔的值时,AoC和CBC的百分比变化最小。

结论

本研究中的体外评估突出了所研究的五种IOL在触觉部和OHJ几何特征上的差异。所收集的证据反驳了所有疏水丙烯酸一体式IOL都相同的观点,并支持了个体IOL可能因个体情况而具有相对优势和劣势的观点。我们认为,由于解剖条件和二次诊断,了解几何形状对于外科医生有机会在个体病例中选择最佳的“定制”选项是必要的。我们的实验台研究表明,目前可用的单焦点疏水丙烯酸晶状体之间的差异有多大。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1f53/8927568/4e9e2b27041f/40123_2022_469_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验