对比增强超声(CEUS)下的肾脏灌注与活体肾供体的肾功能相关。

Kidney Perfusion in Contrast-Enhanced Ultrasound (CEUS) Correlates with Renal Function in Living Kidney Donors.

作者信息

El-Bandar Nasrin, Lerchbaumer Markus H, Peters Robert, Maxeiner Andreas, Kotsch Katja, Sattler Arne, Miller Kurt, Schlomm Thorsten, Hamm Bernd, Budde Klemens, Liefeldt Lutz, Fischer Thomas, Friedersdorff Frank

机构信息

Department of Urology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, 10117 Berlin, Germany.

Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, 10117 Berlin, Germany.

出版信息

J Clin Med. 2022 Feb 1;11(3):791. doi: 10.3390/jcm11030791.

Abstract

Contrast-enhanced ultrasound (CEUS) is a widely used diagnostic tool for analyzing perfusion and characterizing lesions in several organs. However, to date, it has not been sufficiently investigated whether there is an association between CEUS findings and kidney function. This study aimed at identifying the potential relationship between kidney function and the renal perfusion status determined by CEUS in living kidney donors. A total of 30 living kidney donors examined between April 2018 and March 2020 were included in the study. All patients underwent various diagnostic procedures for evaluation of renal function. CEUS was performed in all 30 donors one day before nephrectomy. Kidney perfusion was quantified using a postprocessing tool (VueBox, Bracco Imaging). Various perfusion parameters were subsequently analyzed and compared with the results of the other methods used to evaluate kidney function. Of all parameters, mean signal intensity (MeanLin) had the strongest correlation, showing significant correlations with eGFR (CG) (r = -0.345; = 0.007) and total kidney volume (r = -0.409; = 0.001). While there was no significant correlation between any perfusion parameter and diethylenetriaminepentaacetic acid (DTPA), we detected a significant correlation between MeanLin and DTPA (r = -0.502; = 0.005) in the subgroup of normal-weight donors. The results indicate that signal intensity in CEUS is associated with kidney function in normal-weight individuals. Body mass index (BMI) may be a potential confounder of signal intensity in CEUS. Thus, more research is needed to confirm these results in larger study populations.

摘要

超声造影(CEUS)是一种广泛应用于分析多个器官灌注情况及对病变进行特征描述的诊断工具。然而,迄今为止,尚未充分研究CEUS检查结果与肾功能之间是否存在关联。本研究旨在确定活体肾供体中肾功能与CEUS所测定的肾脏灌注状态之间的潜在关系。共有30名在2018年4月至2020年3月期间接受检查的活体肾供体纳入本研究。所有患者均接受了各种评估肾功能的诊断程序。在所有30名供体肾切除术前一天进行CEUS检查。使用后处理工具(VueBox,百胜医疗)对肾脏灌注进行定量分析。随后分析各种灌注参数,并与用于评估肾功能的其他方法的结果进行比较。在所有参数中,平均信号强度(MeanLin)的相关性最强,与估算肾小球滤过率(CG)(r = -0.345;P = 0.007)和肾脏总体积(r = -0.409;P = 0.001)均呈显著相关。虽然任何灌注参数与二乙三胺五乙酸(DTPA)之间均无显著相关性,但在体重正常的供体亚组中,我们检测到MeanLin与DTPA之间存在显著相关性(r = -0.502;P = 0.005)。结果表明,在体重正常的个体中,CEUS中的信号强度与肾功能相关。体重指数(BMI)可能是CEUS中信号强度的一个潜在混杂因素。因此,需要更多研究在更大的研究人群中证实这些结果。