Weckbach L S, Staneck J L
J Clin Microbiol. 1986 Apr;23(4):700-3. doi: 10.1128/jcm.23.4.700-703.1986.
A biphasic blood culture bottle (BiPB: GIBCO Laboratories, North Andover, Mass.) with an architectural design that physically separates the agar slant from the broth was compared with a conventional vented monophasic bottle (MPB-A) for use in the routine culture of blood. Both bottles contained tryptic soy broth. Tryptic soy agar was used for the BiPB slant. A third unvented bottle (MPB-N) with Columbia broth was included as part of the blood culture set. Of 3,537 sets collected, 444 were positive; 57 of these 444 sets were positive by virtue of an exclusively positive anaerobic bottle. Both BiPB and MPB-A were positive in 235 of the remaining 387 positive sets. A total of 521 isolates was recovered during the study. Of these isolates, 252 were recovered in both the BiPB and the MPB-A from the same set; 105 isolates grew in the BIPB but not in MPB-A, 95 isolates grew only in the MPB-A but not in BiPB, and 69 grew exclusively in the MPB-N. The BiPB allowed more rapid recovery of Candida spp., J-K diphtheroids, Pseudomonas spp. Making BiPB subcultures was easy enough to permit both early and daily subculture, which provided isolated colonies sooner than could be done by using the MPB-A. Isolated colonies and, therefore, identification and susceptibility results were available at least 1 day earlier for the BiPB isolates in approximately 50% of instances when both the BiPB and the MPB-A were positive. Staphylococcus epidermidis and streptococci were recovered more frequently in the BiPB, while gram-positive anaerobes were detected at a significantly (P less than 0.025) more frequent rate in the MPB-A than in the BiPB. Either bottle, however, should be used in conjunction with an anaerobic bottle for optimal recovery of anaerobic bacteria.
将一种具有独特设计(能将琼脂斜面与肉汤在物理上分隔开)的双相血培养瓶(BiPB:GIBCO实验室,马萨诸塞州北安多弗)与用于血液常规培养的传统通气单相瓶(MPB - A)进行了比较。两种瓶子都含有胰蛋白胨大豆肉汤。BiPB的斜面使用胰蛋白胨大豆琼脂。作为血培养套装的一部分,还包括第三个未通气的装有哥伦比亚肉汤的瓶子(MPB - N)。在收集的3537套样本中,444套呈阳性;这444套中有57套仅厌氧瓶呈阳性。在其余387套阳性样本中,BiPB和MPB - A均呈阳性的有235套。在研究期间共分离出521株菌株。在这些分离株中,有252株在同一套样本的BiPB和MPB - A中均被分离出来;105株在BiPB中生长但不在MPB - A中生长,95株仅在MPB - A中生长而不在BiPB中生长,69株仅在MPB - N中生长。BiPB能更快地分离出念珠菌属、JK类白喉杆菌、假单胞菌属。制作BiPB的传代培养物很容易,能够实现早期和每日传代培养,比使用MPB - A能更快地获得分离菌落。在BiPB和MPB - A均为阳性的情况下,大约50%的实例中,BiPB分离株的分离菌落以及鉴定和药敏结果至少提前1天可得。表皮葡萄球菌和链球菌在BiPB中更频繁地被分离出来,而革兰氏阳性厌氧菌在MPB - A中的检出率比在BiPB中显著(P小于0.025)更高。然而,为了最佳地分离厌氧菌,任何一种瓶子都应与一个厌氧瓶联合使用。