In a retrospective fashion, two different blood culture bottles with biphasic brain heat infusion media, one permanently and the other transiently vented, were compared to a transiently vented tryptic soy broth blood culture bottle for the recovery of yeasts from blood. A total of 95 isolates of Candida species and 19 isolates of Cryptococcus neoformans were recovered, of which 95% were from the permanently vented biphasic medium bottle incubated at 30 degrees C, 57% were from the transiently vented biphasic medium bottle incubated at 35 degrees C, and 45% were from the transiently vented tryptic soy broth bottle incubated at 35 degrees C. In 81% of the patients with candidemia, yeasts were detected either only (50%) or earlier (31%) in the permanently vented biphasic blood culture bottle. The mean recovery time was shorter in both biphasic media compared to the tryptic soy broth bottle. Cryptococcus neoformans was not recovered from the transiently vented broth, and less than 50% of the isolates of Candida glabrata and Cryptococcus neoformans grew in the transiently vented biphasic bottle. The results suggest that when fungemia is suspected, the use of a permanently vented biphasic bottle incubated at 30 degrees C will increase the recovery rate of yeasts from blood and that the transiently vented biphasic bottle and tryptic soy broth bottle are less satisfactory for this purpose.
以回顾性方式,将两个装有双相脑心浸液培养基的不同血培养瓶(一个永久通气,另一个临时通气)与一个临时通气的胰蛋白胨大豆肉汤血培养瓶进行比较,以从血液中分离酵母菌。共分离出95株念珠菌属菌株和19株新生隐球菌,其中95%来自于在30℃培养的永久通气双相培养基瓶,57%来自于在35℃培养的临时通气双相培养基瓶,45%来自于在35℃培养的临时通气胰蛋白胨大豆肉汤瓶。在81%的念珠菌血症患者中,在永久通气的双相血培养瓶中仅(50%)或更早(31%)检测到酵母菌。与胰蛋白胨大豆肉汤瓶相比,两种双相培养基的平均恢复时间均较短。在临时通气的肉汤中未分离到新生隐球菌,在临时通气的双相瓶中光滑念珠菌和新生隐球菌的分离株生长率不到50%。结果表明,当怀疑有真菌血症时,使用在30℃培养的永久通气双相瓶可提高血液中酵母菌的回收率,而临时通气的双相瓶和胰蛋白胨大豆肉汤瓶在此方面不太理想。