Suppr超能文献

从对 SARS-CoV-2 RNA 的长期监测中获得的关于 COVID-19 监测的见解:以蒙特雷大都市区(墨西哥)为例。

Acquired insights from the long-term surveillance of SARS-CoV-2 RNA for COVID-19 monitoring: The case of Monterrey Metropolitan Area (Mexico).

机构信息

Escuela de Ingeniería y Ciencias, Tecnologico de Monterrey, Campus Monterrey, Eugenio Garza Sada 2501 Sur, Monterrey, 64849, Mexico.

Escuela de Ingeniería y Ciencias, Tecnológico de Monterrey, Campus Puebla, Atlixcáyotl 5718, Reserva Territorial Atlixcáyotl, Puebla, 72453, Mexico.

出版信息

Environ Res. 2022 Jul;210:112967. doi: 10.1016/j.envres.2022.112967. Epub 2022 Feb 18.

Abstract

Wastewater-based epidemiology offers a time- and cost-effective way to monitor SARS-CoV-2 spread in communities and therefore represents a complement to clinical testing. WBE applicability has been demonstrated in a number of cases over short-term periods as a method for tracking the prevalence of SARS-CoV-2 and an early-warning tool for predicting outbreaks in the population. This study reports SARS-CoV-2 viral loads from wastewater treatment plants (WWTPs) and hospitals over a 6-month period (June to December 2020). Results show that the overall range of viral load in positive tested samples was between 1.2 × 10 and 3.5 × 10 gene copies/l, unveiling that secondary-treated wastewaters mirrored the viral load of influents. The interpretation suggests that the viral titers found in three out of four WWTPs were associated to clinical COVID-19 surveillance indicators preceding 2-7 days the rise of reported clinical cases. The median wastewater detection rate of SARS-CoV-2 was one out of 14,300 reported new cases. Preliminary model estimates of prevalence ranged from 0.02 to 4.6% for the studied period. This comprehensive statistical and epidemiological analysis demonstrates that the applied wastewater-based approach to COVID-19 surveillance is in general consistent and feasible, although there is room for improvements.

摘要

污水流行病学提供了一种时间和成本效益高的方法来监测社区中 SARS-CoV-2 的传播,因此是临床检测的补充。在许多短期案例中,WBE 已经证明了其适用性,可用于追踪 SARS-CoV-2 的流行情况,以及预测人群中爆发的预警工具。本研究报告了污水处理厂(WWTP)和医院在 6 个月期间(2020 年 6 月至 12 月)的 SARS-CoV-2 病毒载量。结果表明,阳性检测样本的总体病毒载量范围在 1.2×10 和 3.5×10 基因拷贝/升之间,揭示了二级处理废水中的病毒载量与进水的病毒载量相吻合。这一解释表明,在四个 WWTP 中有三个 WWTP 的病毒滴度与临床 COVID-19 监测指标相关,这些指标在报告的临床病例增加前 2-7 天就出现了。SARS-CoV-2 在废水中的中位检出率为每 14300 例报告新病例中有一例。研究期间,患病率的初步模型估计值在 0.02 到 4.6%之间。这项全面的统计和流行病学分析表明,应用于 COVID-19 监测的污水基础方法总体上是一致和可行的,尽管仍有改进的空间。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a9da/8853965/de6e13060a3c/ga1_lrg.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验