Morris T W, Hayakawa K, Sahler L G, Ekholm S
Diagn Imaging Clin Med. 1986;55(3):109-13.
Intra-arterial digital subtraction angiography (DSA) can produce coronary artery opacification with isotonic contrast media. In this study we have examined the importance of electrolyte composition in isotonic formulations on the incidence of fibrillation. Right coronary injections of media were made for 25 s in anesthetized dogs. Isotonic meglumine diatrizoate and iohexol produced fibrillation in more than 68% of the injections, while sodium diatrizoate, saline, meglumine/sodium ioxaglate and iohexol with added sodium diatrizoate never produced fibrillation. These animal studies demonstrate a significantly higher risk of fibrillation (p less than 0.005) with isotonic nonionic and ionic media not containing sodium ions.
动脉内数字减影血管造影(DSA)可使用等渗造影剂使冠状动脉显影。在本研究中,我们探讨了等渗制剂中电解质成分对心律失常发生率的影响。在麻醉犬身上进行右冠状动脉造影剂注射,持续25秒。等渗的葡甲胺泛影葡胺和碘海醇在超过68%的注射中会引发心律失常,而泛影酸钠、生理盐水、葡甲胺/碘克沙酸钠以及添加了泛影酸钠的碘海醇从未引发心律失常。这些动物研究表明,不含钠离子的等渗非离子和离子型造影剂引发心律失常的风险显著更高(p小于0.005)。