Reliability and agreement of lumbar multifidus volume and fat fraction quantification using magnetic resonance imaging.
机构信息
KU Leuven - University of Leuven, Department of Development and Regeneration, Herestraat 49, Box 805, B-3000, Leuven, Belgium; University Hospitals Leuven, Department of Physical Medicine and Rehabilitation, Herestraat 49, B-3000, Leuven, Belgium.
University Hospitals Leuven, Department of Physical Medicine and Rehabilitation, Herestraat 49, B-3000, Leuven, Belgium.
出版信息
Musculoskelet Sci Pract. 2022 Jun;59:102532. doi: 10.1016/j.msksp.2022.102532. Epub 2022 Feb 21.
INTRODUCTION
Magnetic resonance imaging (MRI) is the standard to quantify size and structure of lumbar muscles. Three-dimensional volumetric measures are expected to be more closely related to muscle function than two-dimensional measures such as cross-sectional area. Reliability and agreement of a standardized method should be established to enable the use of MRI to assess lumbar muscle characteristics.
OBJECTIVES
This study investigates the intra- and inter-processor reliability for the quantification of (1) muscle volume and (2) fat fraction based on chemical shift MRI images using axial 3D-volume measurements of the lumbar multifidus in patients with low back pain.
METHODS
Two processors manually segmented the lumbar multifidus on the MRI scans of 18 patients with low back pain using Mevislab software following a well-defined method. Fat fraction of the segmented volume was calculated. Reliability and agreement were determined using intra-class correlation coefficients (ICC), Bland-Altman plots and calculation of the standard error of measurement (SEM) and minimal detectable change (MDC).
RESULTS
Excellent ICCs were found for both intra-processor and inter-processor analysis of lumbar multifidus volume measurement, with slightly better results for the intra-processor reliability. The SEMs for volume were lower than 4.1 cm³. Excellent reliability and agreement were also found for fat fraction measures, with ICCs of 0.985-0.998 and SEMs below 0.946%.
CONCLUSION
The proposed method to quantify muscle volume and fat fraction of the lumbar multifidus on MRI was highly reliable, and can be used in further research on lumbar multifidus structure.
简介
磁共振成像(MRI)是量化腰椎肌肉大小和结构的标准。与横截面积等二维测量相比,三维体积测量预计与肌肉功能更为密切相关。应建立标准化方法的可靠性和一致性,以便能够使用 MRI 评估腰椎肌肉特征。
目的
本研究旨在探讨使用化学位移 MRI 图像对腰痛患者腰椎多裂肌进行轴向 3D 体积测量时,(1)肌肉体积和(2)脂肪分数的定量分析的内部和处理器间可靠性。
方法
两名处理器使用 Mevislab 软件按照明确的方法对 18 名腰痛患者的 MRI 扫描进行腰椎多裂肌手动分割。计算分割体积的脂肪分数。使用组内相关系数(ICC)、Bland-Altman 图以及测量误差(SEM)和最小可检测变化(MDC)的计算来确定可靠性和一致性。
结果
腰椎多裂肌体积测量的内部和处理器间分析均显示出极好的 ICC,内部处理器可靠性的结果略好。体积的 SEM 低于 4.1cm³。脂肪分数测量也显示出极好的可靠性和一致性,ICC 为 0.985-0.998,SEM 低于 0.946%。
结论
本研究提出的 MRI 量化腰椎多裂肌肌肉体积和脂肪分数的方法具有高度可靠性,可用于进一步研究腰椎多裂肌结构。