To evaluate the suitability of urine samples collected with cotton balls placed into diapers for routine laboratory chemistry analyses.
Twenty pools of residual unpreserved urine samples were separated into control and treated aliquots. The treated samples were absorbed into 2 different brands of cotton balls, wrapped in 3 different brands of diapers, and incubated at 37°C for 1 hour. The urine-soaked cotton balls were placed into a syringe and expressed via plunger depression. Urine sodium, potassium, creatinine, urea, calcium, magnesium, inorganic phosphorus, albumin, and total protein were measured on all samples on 5 automated clinical chemistry platforms: Ortho Vitros 4600, Siemens Dimension Vista 500, Beckman Coulter AU5822, Roche Cobas 6000, and Abbott Architect c8000 at 5 separate hospital laboratories. Criteria used to exclude the presence of significant effects of urine from presoaked cotton balls in a diaper on the measurement of chemistry laboratory tests were R >0.95, slope of 0.9-1.1, and mean bias within ±10%.
Albumin and total protein measurements demonstrated significant negative bias in urine from both brands of presoaked cotton balls with all brands of diapers on all 5 chemistry platforms compared with the control urine. We did not observe a significant effect of presoaking urine in cotton balls in a diaper on the measurement of sodium, inorganic phosphorus, and urea. The remaining tests demonstrated significant effects when measured in urine from presoaked cotton balls and/or diapers that were specific to the chemistry analyzer platform or diaper.
Diaper and cotton ball-based urine collection significantly impacts the measurement of several common chemistry assays.
评估将置于尿布中的棉球收集的尿液样本用于常规实验室化学分析的适宜性。
将 20 份未经保存的剩余尿液样本分成对照和处理等分试样。处理过的样本被吸收到 2 种不同品牌的棉球中,用 3 种不同品牌的尿布包裹,并在 37°C 下孵育 1 小时。将浸满尿液的棉球放入注射器中,通过推压活塞进行挤压。对所有样本在 5 个自动化临床化学平台(Ortho Vitros 4600、Siemens Dimension Vista 500、Beckman Coulter AU5822、Roche Cobas 6000 和 Abbott Architect c8000)上的 5 个不同医院实验室的尿液钠、钾、肌酐、尿素、钙、镁、无机磷、白蛋白和总蛋白进行了测量。用于排除尿布中预浸泡的棉球对化学实验室测试测量结果有显著影响的标准是 R>0.95、斜率在 0.9-1.1 之间以及均值偏差在±10% 以内。
与对照尿液相比,所有品牌的尿布上 2 种品牌的预浸泡棉球的尿液白蛋白和总蛋白测量结果均显示出显著的负偏差。我们没有观察到尿布和棉球收集的尿液对钠、无机磷和尿素测量有显著影响。其余测试在预浸泡棉球和/或尿布中的尿液进行测量时表现出特定于化学分析仪平台或尿布的显著影响。
尿布和基于棉球的尿液收集方法显著影响几种常见化学分析的测量结果。