Suppr超能文献

眼假体中通过透明丙烯酸树脂对虹膜的放大

Magnification of Iris through Clear Acrylic Resin in Ocular Prosthesis.

作者信息

Rokaya Dinesh, Kritsana Jidapa, Amornvit Pokpong, Dhakal Nagendra, Khurshid Zohaib, Zafar Muhammad Sohail, Saonanon Preamjit

机构信息

Department of Clinical Dentistry, Walailak University International College of Dentistry, Walailak University, Bangkok 10400, Thailand.

Oculoplastic and Reconstructive Surgery Unit, Department of Ophthalmology, Faculty of Medicine, King Chulalongkorn Memorial Hospital, Chulalongkorn University, Bangkok 10330, Thailand.

出版信息

J Funct Biomater. 2022 Mar 11;13(1):29. doi: 10.3390/jfb13010029.

Abstract

The study on the magnification of the clear acrylic resin in prosthetic dentistry is important but lacking. Hence, this research aimed to investigate the magnification of the iris in the ocular prosthesis with various thicknesses of clear heat cure acrylic resin. A total of 60 ocular prostheses were divided into six groups with various thicknesses of clear heat cure acrylic resin over the iris; T0 (control): no acrylic resin, T1: 2, T2: 4, T3: 6, T4: 8, and T5: 10 mm of clear acrylic resin over the iris. Each ocular prosthesis was manufactured from white acrylic, with a 10.250 mm iris. Then, the clear heat cure resin was placed over the iris, cured, then polished. The final diameter of the iris was measured with a vernier caliper. The sizes of the iris were compared among various groups using one-way ANOVA, and a significant level was chosen at p value = 0.01. The mean sizes of iris were T0 = 10.25, T1 = 10.92, T2 = 11.26, T3 = 11.91, T4 = 12.75, and T5 = 13.43 mm. The size of the iris was significantly different among the group (p < 0.0001). The magnification of the iris for different groups was 1.06 for T1, 1.10 for T2, 1.16 for T3, 1.24 for T4, and 1.31 for T5. The magnification of the iris increased as the thickness of clear heat cure acrylic resin over the iris is increased on the ocular prosthesis.

摘要

口腔修复学中透明丙烯酸树脂放大率的研究很重要,但尚显不足。因此,本研究旨在调查不同厚度的透明热固化丙烯酸树脂覆盖下的眼用假体中虹膜的放大率。总共60个眼用假体被分为六组,每组在虹膜上方覆盖不同厚度的透明热固化丙烯酸树脂;T0(对照组):无丙烯酸树脂,T1:2mm,T2:4mm,T3:6mm,T4:8mm,T5:10mm的透明丙烯酸树脂覆盖在虹膜上方。每个眼用假体由白色丙烯酸制成,虹膜直径为10.250mm。然后,将透明热固化树脂放置在虹膜上方,固化,然后抛光。用游标卡尺测量虹膜的最终直径。使用单因素方差分析比较不同组之间虹膜的大小,显著性水平选择为p值 = 0.01。虹膜的平均大小分别为T0 = 10.25mm,T1 = 10.92mm,T2 = 11.26mm,T3 = 11.91mm,T4 = 12.75mm,T5 = 13.43mm。不同组之间虹膜大小存在显著差异(p < 0.0001)。不同组虹膜的放大率分别为T1组1.06,T2组1.10,T3组1.16,T4组1.24,T5组1.31。随着眼用假体上虹膜上方透明热固化丙烯酸树脂厚度的增加,虹膜的放大率也随之增加。