The apparent effect of superior semicircular canal dehiscence (SSCD) on middle ear- and cochlear impedance has led researchers to investigate the use of wideband acoustic immittance as a screening tool when SSCD is suspected. The purpose of the study was to describe the absorbance characteristics and tympanometric values of ears with confirmed SSCD measured at tympanometric peak pressure (TPP) and at ambient pressure.
Wideband Acoustic Immittance was performed at ambient pressure and at TPP on ten participants (12 ears) with confirmed SSCD, as well as on an age- and gender matched control group (12 ears). Inferential statistics were used to determine whether statistical differences existed for the absorbance values at each of the averaged frequencies, the resonance frequency (RF) and tympanometric data between the SSCD and control groups.
The mean absorbance of the SSCD group reached a maximum at 890.9 Hz and a minimum at 6349.6 Hz. When testing absorbance at TPP, a statistically significant increase/peak in the absorbance values of the SSCD group (compared to those of the control group) was found from 630 to 890.9 Hz and a decrease from 4489.8 to 6349.6 Hz. Similar patterns were observed for absorbance at ambient pressure. A lower mean RF for ears with SSCD as well as an increased mean admittance magnitude (AM) value at RF was found compared to those of the control group.
The use of SSCD as a screening tool when SSCD is suspected was strengthened by results similar to those of previous studies. As a result of the significant difference in RF of SSCD ears compared to the RF of the control group, the potential value of measuring the RF of the middle ear to differentiate between mass-and stiffness dominated pathologies, was also illustrated.
上半规管裂(SSCD)对上中耳和耳蜗阻抗的明显影响,促使研究人员在怀疑 SSCD 时将宽带声导抗用作筛查工具。本研究的目的是描述在测压峰值(TPP)和常压下测量的确诊 SSCD 耳的吸收特性和鼓室图值。
对 10 名(12 耳)确诊 SSCD 患者以及年龄和性别匹配的对照组(12 耳)进行常压和 TPP 宽带声导抗检查。采用推断统计学来确定 SSCD 组和对照组在平均频率的吸收值、共振频率(RF)和鼓室图数据上是否存在统计学差异。
SSCD 组的平均吸收值在 890.9 Hz 处达到最大值,在 6349.6 Hz 处达到最小值。在 TPP 测试吸收值时,发现 SSCD 组的吸收值与对照组相比在 630-890.9 Hz 处有显著增加/峰值,在 4489.8-6349.6 Hz 处有下降。在常压下的吸收值也观察到了类似的模式。与对照组相比,SSCD 耳的平均 RF 较低,RF 处的平均导纳幅度(AM)值增加。
当怀疑 SSCD 时,使用 SSCD 作为筛查工具的结论得到了强化,因为 SSCD 耳的 RF 与对照组的 RF 存在显著差异,这表明测量中耳 RF 以区分质量和刚度为主导的病理的潜在价值。