Suppr超能文献

与健康受试者相比,使用超高速Scheimpflug相机对原发性开角型青光眼进行角膜生物力学评估:文献的荟萃分析

Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature.

作者信息

Catania Fiammetta, Morenghi Emanuela, Rosetta Pietro, Paolo Vinciguerra, Vinciguerra Riccardo

机构信息

Department of Biomedical Sciences, Humanitas University, Milan, Italy.

Humanitas Clinical and Research Center, IRCCS, Rozzano, Italy.

出版信息

Curr Eye Res. 2023 Feb;48(2):161-171. doi: 10.1080/02713683.2022.2059809. Epub 2022 Apr 18.

Abstract

PURPOSE

The aim of this meta-analysis of the literature is to provide a comprehensive analysis of the differences in Corvis ST dynamic corneal response (DCR) parameters between primary open-angle glaucoma (POAG) patients and healthy controls.

METHODS

A quantitative meta-analysis was conducted on articles published before September 10, 2021 identified by searching PubMed, EMBASE, and Web of Science. Prospective studies comparing DCR Corvis ST parameter in high tension POAG and healthy controls were included. The random-effects model was conducted. Assessment of heterogeneity was based on the calculation of . Funnel plots evaluation and meta-regression were performed in case of detection of high heterogeneity.

RESULTS

The selection process resulted in the inclusion of six articles. Pooled analysis revealed that POAG corneas respond to mechanical stimulus with a smaller concavity, showing lower deformation amplitude (DA) (CI95% -0.991 to -0.578; < .001; = 0%), higher highest concavity radius (HCR; confidence interval [CI]95% -0.01 to 0.34; = .058; = 6.7%), and lower peak distance (PD; CI95% -1.06 to -0.024; = .040; = 86.5%). They also show a slower loading phase, with lower highest concavity time (HCT; CI95% -0.39 to -0.02; = .029; = 3.3%) and lower applanation velocity-1 (CI95% -0.641 to -0.127; = .003; = 34.6%), and a faster restoration to the original form, shown by lower applanation time-2 (CI95% -1.123 to -0.544; = .001; = 44.8%) compared to healthy subjects.

CONCLUSIONS

High tension POAG patients are characterized by stiffer corneas compared to healthy controls. These differences are valid also after removing the effect of age, corneal thickness, and intraocular pressure (IOP).

摘要

目的

本荟萃分析旨在全面分析原发性开角型青光眼(POAG)患者与健康对照者之间Corvis ST动态角膜反应(DCR)参数的差异。

方法

对通过检索PubMed、EMBASE和Web of Science确定的2021年9月10日前发表的文章进行定量荟萃分析。纳入比较高眼压POAG患者与健康对照者DCR Corvis ST参数的前瞻性研究。采用随机效应模型。基于 的计算进行异质性评估。若检测到高度异质性,则进行漏斗图评估和荟萃回归。

结果

筛选过程共纳入6篇文章。汇总分析显示,POAG角膜对机械刺激的反应凹度较小,表现为较低的变形幅度(DA)(95%置信区间[CI] -0.991至 -0.578; <.001; = 0%)、较高的最大凹度半径(HCR;95%置信区间[CI] -0.01至0.34; =.058; = 6.7%)和较低的峰值距离(PD;95%置信区间[CI] -1.06至 -0.024; =.040; = 86.5%)。与健康受试者相比,POAG角膜还表现出较慢的加载阶段,即较低的最大凹度时间(HCT;95%置信区间[CI] -0.39至 -0.02; =.029; = 3.3%)和较低的压平速度-1(95%置信区间[CI] -0.641至 -0.127; =.003; = 34.6%),以及更快恢复到原始形态,表现为较低的压平时间-2(95%置信区间[CI] -1.123至 -0.544; =.001; = 44.8%)。

结论

与健康对照者相比,高眼压POAG患者的角膜更硬。去除年龄、角膜厚度和眼压(IOP)的影响后,这些差异仍然存在。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验