Suppr超能文献

前列腺磁共振成像:直肠内线圈是否必要?——一篇综述。

Prostate MRI: Is Endorectal Coil Necessary?-A Review.

作者信息

Lee Grace, Oto Aytekin, Giurcanu Mihai

机构信息

Department of Radiology, University of Chicago, 5841 South Maryland Avenue, Chicago, IL 60637, USA.

Department of Public Health Sciences, University of Chicago, 5841 South Maryland Avenue, Chicago, IL 60637, USA.

出版信息

Life (Basel). 2022 Apr 11;12(4):569. doi: 10.3390/life12040569.

Abstract

To assess the necessity of endorectal coil use in 3 Tesla (T) prostate magnetic resonance imaging (MRI), a literature review comparing the image quality and diagnostic performance with an endorectal coil (ERC) and a without endorectal coil (NERC), with a phased array coil or a wearable perineal coil (WPC), was performed. A PubMed search of 3T prostate MRI using an endorectal coil for studies published until 31 July 2021 was performed. A total of 14 studies comparing 3T prostate MRI with and without endorectal coil use were identified. The quality scores and diagnostic performances were recorded for each study. In total, five studies compared image quality; five studies compared quality and performance; and four studies compared performance of detection, size of detected lesions, accuracy of cancer localization, and aggressiveness/staging. The use of an endorectal coil improved image quality with a higher overall signal to noise ratio, posterior and peripheral zone signal to noise ratio, high b-value attenuation diffusion coefficient (ADC) signal to noise ratio, and contrast to noise ratio. Endorectal coil use improved subjective image quality for anatomic detail on T2 weighted images (T2WI) and diffusion weighted images (DWI). Endorectal coil use had less motion artifact on DWI than non-endorectal coil use, but produced a higher occurrence of other artifacts on DWI. Endorectal coils had higher sensitivity, specificity, and positive predictive value (PPV) in the detection of overall and index lesions, as well as smaller and less aggressive lesions, missing fewer and smaller lesions than non-endorectal coils. Endorectal coils had higher sensitivity than non-endorectal coils in localizing and staging lesions. Endorectal coils improved quantitative and qualitative image quality and diagnostic performance in the detection of smaller and less aggressive cancers in 3T prostate MRI.

摘要

为评估在3特斯拉(T)前列腺磁共振成像(MRI)中使用直肠内线圈的必要性,我们进行了一项文献综述,比较了使用直肠内线圈(ERC)和不使用直肠内线圈(NERC),以及使用相控阵线圈或可穿戴会阴线圈(WPC)时的图像质量和诊断性能。我们在PubMed上搜索了截至2021年7月31日发表的使用直肠内线圈进行3T前列腺MRI的研究。共识别出14项比较使用和不使用直肠内线圈的3T前列腺MRI的研究。记录了每项研究的质量评分和诊断性能。总体而言,五项研究比较了图像质量;五项研究比较了质量和性能;四项研究比较了检测性能、检测到的病变大小、癌症定位准确性以及侵袭性/分期。使用直肠内线圈可提高图像质量,具有更高的总体信噪比、后部和外周区信噪比、高b值衰减扩散系数(ADC)信噪比以及对比噪声比。使用直肠内线圈可提高T2加权图像(T2WI)和扩散加权图像(DWI)上解剖细节的主观图像质量。与不使用直肠内线圈相比,使用直肠内线圈在DWI上的运动伪影更少,但在DWI上产生其他伪影的发生率更高。在检测总体病变和索引病变以及较小和侵袭性较小的病变方面,直肠内线圈具有更高的敏感性、特异性和阳性预测值(PPV), 比非直肠内线圈遗漏的病变更少、更小。在病变定位和分期方面,直肠内线圈比非直肠内线圈具有更高的敏感性。直肠内线圈在3T前列腺MRI中检测较小和侵袭性较小的癌症时,可提高定量和定性图像质量以及诊断性能。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/21aa/9030903/14b6c89411a5/life-12-00569-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验