Abstract

OBJECTIVE

The purpose of this study was to examine the interrater reliability of using a tape measure and goniometer to measure thoracolumbar range of motion (ROM).

METHODS

Seven raters were trained on procedures for evaluating ROM of 4 spine motions, using 12 measurement procedures with a tape measure (n = 8) and a goniometer (n = 4). Three healthy female graduate student volunteers who reported having no injuries and who were able to perform all spinal movements served were stationed in separate rooms, and the 7 raters rotated through the rooms and measured each of the spine motions, using a total of the 12 measurement procedures. Data were analyzed using intraclass correlation coefficient (ICC) with a 95% confidence interval (CI) as an index of reliability.

RESULTS

Interrater reliability ranged from ICC of 0.791 to 0.999, indicating good-to-strong reliability. The flexion finger-floor measurement showed strongest reliability, with an ICC of 0.999 (95% CI, 0.998-1.00). Interrater reliability was high for the modified Schober test (ICC, 0.942; 95% CI, 0.875-0.976), left (ICC, 0.985; 95% CI, 0.969-0.993) and right (ICC, 0.961; 95% CI, 0.920-0.983) lateral flexion, forward flexion (ICC, 0.971; 95% CI, 0.938-0.987) and backward extension (ICC, 0.995; 95% CI, 0.990-0.998), and trunk rotation (ICC, 0.933; 95% CI, 0.857-0.989).

CONCLUSION

In this study, thoracolumbar ROM measurements were obtained using a tape measure and goniometer with a good to high degree of reliability among raters who were trained in accurate procedures with the tape measure and goniometer.

摘要

目的

本研究旨在检验使用卷尺和角度计测量胸腰椎活动范围(ROM)时评分者间的可靠性。

方法

对七名评分者进行培训,使其掌握评估四种脊柱运动ROM的程序,使用卷尺(n = 8)和角度计(n = 4)的12种测量程序。三名报告无损伤且能够进行所有脊柱运动的健康女研究生志愿者被安置在不同房间,七名评分者轮流进入房间,使用总共12种测量程序测量每种脊柱运动。以组内相关系数(ICC)及95%置信区间(CI)作为可靠性指标对数据进行分析。

结果

评分者间可靠性范围为ICC 0.791至0.999,表明可靠性良好至较强。屈曲指地测量显示出最强的可靠性,ICC为0.999(95%CI,0.998 - 1.00)。改良Schober试验(ICC,0.942;95%CI,0.875 - 0.976)、左侧(ICC,0.985;95%CI,0.969 - 0.993)和右侧(ICC,0.961;95%CI,0.920 - 0.983)侧屈、前屈(ICC,0.971;95%CI,0.938 - 0.987)和后伸(ICC,0.995;95%CI,0.990 - 0.998)以及躯干旋转(ICC,0.933;95%CI,0.857 - 0.989)的评分者间可靠性较高。

结论

在本研究中,使用卷尺和角度计获得的胸腰椎ROM测量值在接受卷尺和角度计准确程序培训的评分者之间具有良好至高的可靠性。

相似文献

4
Validation of a method to assess range of motion of the cervical spine using a tape measure.一种使用卷尺评估颈椎活动范围方法的验证
J Manipulative Physiol Ther. 2013 Oct;36(8):538-45. doi: 10.1016/j.jmpt.2013.07.005. Epub 2013 Sep 9.

引用本文的文献

本文引用的文献

4
Accuracy of measuring lateral flexion of the spine with a tape.用卷尺测量脊柱侧屈的准确性。
Clin Biomech (Bristol). 1986 May;1(2):85-9. doi: 10.1016/0268-0033(86)90081-1.