Yamada T, Fukazawa Y, Shiokawa Y, Kosakai N
Jpn Circ J. 1986 Dec;50(12):1253-5. doi: 10.1253/jcj.50.1253.
The Culturette Brand 10-Minute Group A Strep ID test kit (Marion Scientific, Division of Marion Laboratories, Inc., Kansas City, Mo.) was evaluated for its sensitivity and specificity in identifying the group A streptococci directly from 96 throat swabs, against the conventional culture method and serological grouping test. Our results indicated that the rapid test kit and conventional method are 93.8% accurate; percent sensitivity and specificity of the rapid test was 80.6% and 100%, respectively. None of the false-positive observed in rapid test kits occurred with the heterogeneous microorganisms. More than 8 X 10(4) colony forming unit per swab was required for the positive latex agglutination of the test kit. Since the Culturette method is simple to perform and correctly identifies group A streptococcal antigen, and also required no special instruments, it appears to be applicable in hospital laboratories and outpatients clinics.