Boutelle M G, Stanford C, Fillenz M, Albery W J, Bartlett P N
Neurosci Lett. 1986 Dec 23;72(3):283-8. doi: 10.1016/0304-3940(86)90527-6.
Brain glucose concentration was measured with an amperometric enzyme electrode using glucose oxidase (EC 1.1.3.4) irreversibly adsorbed onto an organic conducting salt. The responses of the electrode and its stability both in vitro and in vivo are described. Parellel changes in brain glucose and blood glucose (measured in samples from an implanted intra-atrial cannula) following injections of insulin are reported.
使用不可逆吸附在有机导电盐上的葡萄糖氧化酶(EC 1.1.3.4)的安培酶电极测量脑葡萄糖浓度。描述了该电极在体外和体内的响应及其稳定性。报告了注射胰岛素后脑葡萄糖和血糖(从植入的心房插管采集的样本中测量)的平行变化。