Suppr超能文献

聚多巴胺包覆皮下注射针作为一种微萃取装置,用于通过直接进样质谱/质谱法测定口腔液中的三环类抗抑郁药。

Polydopamine coated hypodermic needles as a microextraction device for the determination of tricyclic antidepressants in oral fluid by direct infusion MS/MS.

作者信息

Vejar-Vivar Carmina, García-Valverde María Teresa, Mardones Claudia, Lucena Rafael, Cárdenas Soledad

机构信息

Affordable and Sustainable Sample Preparation (AS2P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba Campus de Rabanales, Edificio Marie Curie E-14071 Córdoba Spain

Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción Casilla 237, Correo 3 Concepción Chile.

出版信息

RSC Adv. 2021 Jun 28;11(37):22683-22690. doi: 10.1039/d1ra02721b. eCollection 2021 Jun 25.

Abstract

In-needle microextraction consists of the confinement of the sorbent, by coating or packing, inside a metallic needle. The size of the needles reduces the eluent requirements providing an efficient preconcentration of the analytes. In this work, hypodermic needles coated with polydopamine (PDA) are presented as microextraction devices to isolate six tricyclic antidepressants from oral fluid samples. The coating consists of the in-surface polymerization of dopamine at pH 8.5 and mild conditions (room temperature and water as solvent). The PDA coating over the stainless-steel surface confers the needles with a high extraction ability towards the target analytes. After the extraction, the eluates were analyzed by direct infusion MS spectrometry, working in multiple reaction monitoring (MRM) mode, which provided a sample throughput of 30 samples per hour. The variables affecting the synthesis (number of coating cycles, the concentration of dopamine, and needle surface pre-treatment) and the extraction (sample salinity, sample loading cycles, and the number of elution strokes) were studied in depth. Under the optimum conditions, a matrix-matched calibration model was built. The limits of quantification are between 2 and 5 ng mL with linear ranges up to 1000 ng mL for all analytes. The precision, expressed as relative standard deviation (RSD), is better than 10% for all analytes. Accuracy was calculated as recovery, and the obtained values are between 84% and 107%. A single-blind assay was also performed to evaluate the suitability of the method for real application.

摘要

针内微萃取是通过涂覆或填充将吸附剂限制在金属针内部。针的尺寸减小了洗脱液的需求量,可对分析物进行高效预富集。在本研究中,提出了涂覆聚多巴胺(PDA)的皮下注射针作为微萃取装置,用于从口腔液样本中分离六种三环类抗抑郁药。涂层是通过多巴胺在pH 8.5及温和条件(室温,以水为溶剂)下的表面聚合形成的。不锈钢表面的PDA涂层赋予针对于目标分析物的高萃取能力。萃取后,通过直接进样质谱法在多反应监测(MRM)模式下对洗脱液进行分析,每小时可处理30个样品。深入研究了影响合成的变量(涂层循环次数、多巴胺浓度和针表面预处理)以及萃取的变量(样品盐度、样品加载循环次数和洗脱冲程数)。在最佳条件下,建立了基质匹配校准模型。所有分析物的定量限在2至5 ng/mL之间,线性范围高达1000 ng/mL。以相对标准偏差(RSD)表示的精密度对于所有分析物均优于10%。准确度以回收率计算,所得值在84%至107%之间。还进行了单盲试验以评估该方法在实际应用中的适用性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/7dbc/9034363/1e609cb73901/d1ra02721b-f1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验