The dipstrip test for urinary nitrite is fairly unreliable in symptomatic urinary infections and only 104 (52%) of 200 symptomatic children with urinary infection attending an emergency department had a positive result. The test yielded positive results, however, in 83 of 100 outpatients with largely asymptomatic urinary infection attending a follow up clinic because of known predisposition to urinary infection. This difference was highly significant. The finding of urinary nitrite is highly specific for urinary infection and only 1% of 300 uninfected urine specimens gave a positive result. After addition of a broth culture of Escherichia coli to sterile urine incubation at 37 degrees C for four to six hours was required before the nitrite test yielded positive results. This suggests that frequency of micturition in urinary infection reduces the reliability of the nitrite test. On the other hand, the use of overnight, first morning urine specimens may further improve the sensitivity. If nitrite testing is used for screening for urinary infection at home, however, patients should be warned not to rely on a negative result in the presence of symptoms of urinary infection.
用于检测尿中亚硝酸盐的试纸条检测法在有症状的泌尿系统感染中相当不可靠,在一家急诊科就诊的200名有症状的泌尿系统感染儿童中,只有104名(52%)检测结果呈阳性。然而,在因已知易患泌尿系统感染而到随访门诊就诊的100名基本无症状的泌尿系统感染门诊患者中,该检测有83例呈阳性结果。这种差异非常显著。尿中亚硝酸盐的检测结果对泌尿系统感染具有高度特异性,300份未感染的尿液标本中只有1%检测呈阳性。向无菌尿液中加入大肠杆菌肉汤培养物后,在37摄氏度下孵育4至6小时,亚硝酸盐检测才会得出阳性结果。这表明泌尿系统感染时的排尿频率会降低亚硝酸盐检测的可靠性。另一方面,使用过夜的晨尿标本可能会进一步提高检测的敏感性。然而,如果在家中使用亚硝酸盐检测来筛查泌尿系统感染,应提醒患者,在出现泌尿系统感染症状时,不要依赖检测结果为阴性。