Suppr超能文献

应用电位断层扫描:一种评估胃功能的新型非侵入性技术。

Applied potential tomography: a new non-invasive technique for assessing gastric function.

作者信息

Mangnall Y F, Baxter A J, Avill R, Bird N C, Brown B H, Barber D C, Seagar A D, Johnson A G, Read N W

出版信息

Clin Phys Physiol Meas. 1987;8 Suppl A:119-29. doi: 10.1088/0143-0815/8/4a/016.

Abstract

Applied potential tomography is a new, non-invasive technique that yields sequential images of the resistivity of gastric contents after subjects have ingested a liquid or semi-solid meal. This study validates the technique as a means of measuring gastric emptying. Experiments in vitro showed an excellent correlation between measurements of resistivity and either the square of the radius of a glass rod or the volume of water in a spherical balloon when both were placed in an oval tank containing saline. Altering the lateral position of the rod in the tank did not alter the values obtained. Images of abdominal resistivity were also directly correlated with the volume of air in a gastric balloon. Profiles of gastric emptying of liquid meals obtained using APT were very similar to those obtained using scintigraphy or dye dilution techniques provided that acid secretion was inhibited by cimetidine. Profiles of emptying of a mashed potato meal using APT were also very similar to those obtained by scintigraphy. Measurements of the emptying of a liquid meal from the stomach were reproducible if acid secretion was inhibited by cimetidine. Thus, APT is an accurate and reproducible method of measuring gastric emptying of liquids and particulate food. It is inexpensive, well tolerated, easy to use and ideally suited for multiple studies in patients, even those who are pregnant. A preliminary study is also presented that assesses the technique as a means of measuring gastric acid secretion. Comparison of resistivity changes with measured acid secretion following the injection of pentagastrin shows good correlations. APT might offer a non-invasive alternative to the use of a nasogastric tube and acid collection.

摘要

应用电位断层扫描是一种新的非侵入性技术,在受试者摄入液体或半固体食物后,可生成胃内容物电阻率的连续图像。本研究验证了该技术作为测量胃排空的一种方法的有效性。体外实验表明,当将玻璃棒半径的平方或球形气球中的水量置于装有盐水的椭圆形水箱中时,电阻率测量值与它们之间具有极好的相关性。改变水箱中玻璃棒的横向位置不会改变所得值。腹部电阻率图像也与胃气球中的空气量直接相关。如果用西咪替丁抑制胃酸分泌,使用APT获得的液体食物胃排空曲线与使用闪烁扫描法或染料稀释技术获得的曲线非常相似。使用APT获得的土豆泥食物排空曲线也与闪烁扫描法获得的曲线非常相似。如果用西咪替丁抑制胃酸分泌,胃中液体食物排空的测量结果是可重复的。因此,APT是一种准确且可重复的测量液体和颗粒食物胃排空的方法。它价格低廉、耐受性好、易于使用,非常适合对患者进行多项研究,甚至适用于孕妇。还介绍了一项初步研究,该研究评估了该技术作为测量胃酸分泌的一种方法。注射五肽胃泌素后,将电阻率变化与测得的胃酸分泌进行比较,显示出良好的相关性。APT可能为使用鼻胃管和胃酸收集提供一种非侵入性替代方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验