To assess spinal stability in different physiological positions whilst weight-bearing.
A cone beam CT scanner (CBCT) was used to identify any abnormal motion in the spine in different physiological positions whilst weight-bearing. The lumbar spine was assessed in 6 different patients with a comfortable neutral standing position and standing flexion and extension images in selected patients. Seated, weight-bearing flexion and extension images of the cervical spine were obtained in a further patient. Clinical indications included stability assessment post-trauma, post-surgical fusion and back pain. The projection images were reconstructed using bone and soft tissue algorithms to give isotropic CT images which could be viewed as per conventional multi-detector CT images. The flexion and extension CBCT data were fused to give a representation of any spinal movement between the extremes of motion.
The flexion and extension weight-bearing images gave anatomical detail of the spine. Detail of the surgical constructs was possible. Dynamic structural information about spinal alignment, facet joints, exit foramina and paraspinal musculature was possible. The effective dose from the neutral position was equal to that of supine, multi-detector CT.
CBCT can be used to image the lumbar and cervical spine in physiological weight-bearing positions and at different extremes of spinal motion. This novel application of an existing technology can be used to aid surgical decision making to assess spinal stability and to investigate occult back and leg pain. Its use should be limited to specific clinical indications, given the relatively high radiation dose.
评估不同生理位负重状态下脊柱的稳定性。
使用锥形束 CT 扫描仪(CBCT)在不同生理位负重状态下识别脊柱的异常运动。对 6 例患者的舒适中立位和站立位屈伸位图像进行腰椎评估,并对部分患者进行站立位屈伸位检查。对 1 例患者进行颈椎坐位、负重屈伸位 CBCT 检查。临床适应证包括创伤后、手术后融合和腰痛的稳定性评估。使用骨和软组织算法重建投影图像,获得各向同性 CT 图像,可按常规多探测器 CT 图像进行观察。将屈伸 CBCT 数据融合,以显示运动极限之间的任何脊柱运动。
负重屈伸位 CBCT 图像提供了脊柱的解剖细节。可显示手术结构。可获得脊柱排列、关节突关节、出口孔和椎旁肌肉的动态结构信息。中立位的有效剂量与仰卧位多探测器 CT 相同。
CBCT 可用于成像生理负重位和脊柱运动极限的腰椎和颈椎。该现有技术的新应用可用于辅助手术决策,评估脊柱稳定性和调查隐匿性腰背腿痛。由于辐射剂量相对较高,应将其使用限于特定的临床适应证。