Suppr超能文献

使用TRUShape、TruNatomy和WaveOne Gold对弯曲根管中根尖部挤出碎屑进行定量评估。

Quantitative evaluation of apically extruded debris using TRUShape, TruNatomy, and WaveOne Gold in curved canals.

作者信息

Roshdy Nehal Nabil, Hassan Reham

机构信息

Department of Endodontics, Faculty of Dentistry, Cairo University, Giza, Egypt.

Department of Endodontics, Faculty of Dentistry, Minia Univeristy, Giza, Egypt.

出版信息

BDJ Open. 2022 May 20;8(1):13. doi: 10.1038/s41405-022-00106-8.

Abstract

OBJECTIVE

This study compared the quantity of extruded debris after instrumentation with TRUShape 3D Conforming files, TruNatomy files, and the WaveOne Gold reciprocating system.

MATERIALS AND METHODS

Fifty-one mesiobuccal canals with severe curvatures (25-40°) were assigned to three equal groups according to the rotary system used for preparation, either TRUShape, TruNatomy, or WaveOne Gold files. The extruded debris was collected in pre-weighed glass vials. The data were statistically analyzed using a one-way ANOVA test and Tukey's post hoc test.

RESULTS

The least extruded debris was obtained with the WaveOne Gold instruments compared to the TRUShape and TruNatomy files (p < 0.001).

CONCLUSIONS

Debris extrusion occurs independently of the motion or design of the instrument. The WaveOne Gold system outperformed TRUShape and TruNatomy files in this study.

摘要

目的

本研究比较了使用TRUShape 3D适形锉、TruNatomy锉和WaveOne Gold往复式系统进行根管预备后挤出碎屑的量。

材料与方法

将51条严重弯曲(25 - 40°)的近中颊根管根据用于预备的旋转系统分为三组,每组数量相等,分别使用TRUShape、TruNatomy或WaveOne Gold锉。将挤出的碎屑收集在预先称重的玻璃小瓶中。使用单因素方差分析和Tukey事后检验对数据进行统计学分析。

结果

与TRUShape和TruNatomy锉相比,WaveOne Gold器械挤出的碎屑最少(p < 0.001)。

结论

碎屑挤出与器械的运动或设计无关。在本研究中,WaveOne Gold系统的表现优于TRUShape和TruNatomy锉。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ed3b/9122899/5dc305be5517/41405_2022_106_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验