Suppr超能文献

薄正常角膜、顿挫型圆锥角膜和全飞秒激光微小切口基质透镜切除术术后角膜的生物力学差异

Differences of Corneal Biomechanics Among Thin Normal Cornea, Forme-Fruste Keratoconus, and Cornea After SMILE.

作者信息

Zhang Di, Tian Lei, Zhang Haixia, Zheng Yan, Fu Caiyun, Zhai Changbin, Jie Ying, Li Lin

机构信息

School of Biomedical Engineering, Capital Medical University, Beijing, China.

Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China.

出版信息

Front Bioeng Biotechnol. 2022 May 13;10:861924. doi: 10.3389/fbioe.2022.861924. eCollection 2022.

Abstract

To compare the corneal biomechanics of thin normal cornea (TNC) with thinnest corneal thickness (TCT) (≤500 µm), forme-fruste keratoconus (FFKC) and cornea after small incision lenticule extraction (Post-SMILE) had their central corneal thickness (CCT) matched by Corneal Visualization Scheimpflug Technology (Corvis ST). CCT were matched in 23 eyes with FFKC, 23 eyes by SMILE in 3 months post-operatively, and 23 TNC eyes. The differences in corneal biomechanics by Corvis ST among the three groups were compared. There was no significant difference in CCT among the three groups, and the biomechanically corrected intraocular pressure (bIOP) did not differ significantly among the three groups (all > 0.05). There were significant differences in most DCR parameters between pre- and post-operatively (all < 0.05). Compared with TNC, the values of corneal deflection amplitude during the first applanation (A1DA), length at the first applanation (A1L), corneal deflection amplitude during the second applanation (A2DA), and maximum deformation amplitude (DA) decreased in 3 months after SMILE (all < 0.05), these values increased in the FFKC (all < 0.05). The majority of the DCR parameters were different among the three groups. The parameters A1DA, A1L, A2DA, and DA may be different between TNC and Post-SMILE, TNC and FFKC, and Post-SMILE and FFKC.

摘要

为比较角膜最薄处厚度(TCT)≤500 µm的薄正常角膜(TNC)、顿挫型圆锥角膜(FFKC)和小切口透镜切除术(SMILE)后角膜的生物力学特性,采用角膜可视化Scheimpflug技术(Corvis ST)使它们的中央角膜厚度(CCT)匹配。对23只FFKC眼、23只SMILE术后3个月的眼以及23只TNC眼进行了CCT匹配。比较了三组通过Corvis ST测得的角膜生物力学差异。三组间CCT无显著差异,三组间生物力学校正眼压(bIOP)也无显著差异(均P>0.05)。术前和术后大多数动态轮廓图(DCR)参数有显著差异(均P<0.05)。与TNC相比,SMILE术后3个月时首次压平期间角膜偏转幅度(A1DA)、首次压平长度(A1L)、第二次压平期间角膜偏转幅度(A2DA)和最大变形幅度(DA)的值均降低(均P<0.05),这些值在FFKC中升高(均P<0.05)。三组间大多数DCR参数不同。TNC与SMILE术后、TNC与FFKC、SMILE术后与FFKC之间的A1DA、A1L、A2DA和DA参数可能不同。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验