Corvis ST 参数在区分正常、未定型、亚临床和临床圆锥角膜眼中的表现,包括更新的应力度-应变指数。

Performance of Corvis ST Parameters Including Updated Stress-Strain Index in Differentiating Between Normal, Forme-Fruste, Subclinical, and Clinical Keratoconic Eyes.

机构信息

National Clinical Research Center for Ocular Diseases, Eye Hospital, WenZhou Medical University (Y.-Y.M., Z.-X.Q., B.-W.W., H.X., P.W., X.-B.Z., J.-J.W., Y.-F.Y., S.-H.C., F.-J.B), Wenzhou, Zhejiang, China.

Shanghai Eighth People's Hospital (X.-M.M.), Shanghai, China.

出版信息

Am J Ophthalmol. 2024 Feb;258:196-207. doi: 10.1016/j.ajo.2023.10.015. Epub 2023 Oct 24.

Abstract

PURPOSE

This study seeks to evaluate the ability of the updated stress strain index (SSIv2) and other Corvis ST biomechanical parameters in distinguishing between keratoconus at different disease stages and normal eyes.

DESIGN

Diagnostic accuracy analysis to distinguish disease stages.

METHODS

1084 eyes were included and divided into groups of normal (199 eyes), forme fruste keratoconus (FFKC, 194 eyes), subclinical keratoconus (SKC, 113 eyes), mild clinical keratoconus (CKC-Ⅰ, 175 eyes), moderate clinical keratoconus (CKC-Ⅱ, 204 eyes), and severe clinical keratoconus (CKC-Ⅲ, 199 eyes). Each eye was subjected to a Corvis ST examination to determine the central corneal thickness (CCT), biomechanically corrected intraocular pressure (bIOP), SSIv2 (updated stress-strain index), and other 8 Corvis parameters including the stress-strain index (SSIv1), stiffness parameter at first applanation (SP-A1), first applanation time (A1T), Ambrósio relational thickness to the horizontal profile (ARTh), integrated inverse radius (IIR), maximum deformation amplitude (DAM), ratio between deformation amplitude at the apex and at 2 mm nasal and temporal (DARatio2), and Corvis biomechanical index (CBI). The sensitivity and specificity of these parameters in diagnosing keratoconus were analyzed through receiver operating characteristic curves.

RESULTS

Before and after correction for CCT and bIOP, SSIv2 and ARTh were significantly higher and IIR and CBI were significantly lower in the normal group than in the FFKC group, SKC group and the 3 CKC groups (all P < .05). There were also significant correlations between the values of SSIv2, ARTh, IIR, CBI, and the CKC severity (all P < .05). AUC of SSIv2 was significantly higher than all other Corvis parameters in distinguishing normal eyes from FFKC, followed by IIR, ARTh and CBI.

CONCLUSION

Corvis ST's updated stress-strain index, SSIv2, demonstrated superior performance in differentiating between normal and keratoconic corneas, and between corneas with different keratoconus stages. Similar, but less pronounced, performance was demonstrated by the IIR, ARTh and CBI.

摘要

目的

本研究旨在评估更新的应力应变指数(SSIv2)和其他 Corvis ST 生物力学参数在区分不同疾病阶段的圆锥角膜和正常眼方面的能力。

设计

用于区分疾病阶段的诊断准确性分析。

方法

纳入 1084 只眼,分为正常组(199 只眼)、可疑圆锥角膜组(FFKC,194 只眼)、亚临床圆锥角膜组(SKC,113 只眼)、轻度临床圆锥角膜组(CKC-Ⅰ,175 只眼)、中度临床圆锥角膜组(CKC-Ⅱ,204 只眼)和重度临床圆锥角膜组(CKC-Ⅲ,199 只眼)。对每只眼进行 Corvis ST 检查,以确定中央角膜厚度(CCT)、生物力学校正眼压(bIOP)、SSIv2(更新的应力应变指数)和其他 8 个 Corvis 参数,包括应力应变指数(SSIv1)、第一次压平的刚性参数(SP-A1)、第一次压平时间(A1T)、Ambrósio 水平轮廓的关系厚度(ARTh)、整合逆半径(IIR)、最大变形幅度(DAM)、顶点和 2mm 鼻颞侧变形幅度之比(DARatio2)和 Corvis 生物力学指数(CBI)。通过受试者工作特征曲线分析这些参数在诊断圆锥角膜中的灵敏度和特异性。

结果

在校正 CCT 和 bIOP 之前和之后,正常组的 SSIv2 和 ARTh 均显著高于 FFKC 组、SKC 组和 3 个 CKC 组,而 IIR 和 CBI 则显著低于 FFKC 组、SKC 组和 3 个 CKC 组(均 P <.05)。SSIv2、ARTh、IIR、CBI 值与 CKC 严重程度之间也存在显著相关性(均 P <.05)。SSIv2 在区分正常眼与 FFKC 眼、区分不同 CKC 阶段的角膜方面的 AUC 显著高于其他所有 Corvis 参数,其次是 IIR、ARTh 和 CBI。

结论

Corvis ST 的更新的应力应变指数 SSIv2 在区分正常角膜和圆锥角膜以及不同圆锥角膜阶段的角膜方面表现出优异的性能。IIR、ARTh 和 CBI 的性能相似,但不那么明显。