Department of Physiotherapy, Federal University of Bahia, Salvador, Bahia, Brazil; Department of Physiotherapy, State University of Bahia, Salvador, Bahia, Brazil.
Department of Physiotherapy, Federal University of Bahia, Salvador, Bahia, Brazil.
Heart Lung. 2022 Nov-Dec;56:8-23. doi: 10.1016/j.hrtlng.2022.05.011. Epub 2022 May 29.
It is important to clarify the effect of ventilator hyperinflation(VHI) on pulmonary function and secretion clearance in adults receiving mechanical ventilation(MV). There is no published meta-analysis on the effects VHI on pulmonary function and secretion clearance in adults receiving MV. Objective Analyze the published randomized clinical trials(RCTs) that investigated the effects of VHI on pulmonary function and secretion clearance in adults receiving MV, comparing VHI with isolated aspiration, VHI with manual hyperinflation(MHI), VHI +vibrocompression(VB) versus VB and VHI+VB versus isolated aspiration.
The following databases PubMed, LILACS, EMBASE, SciELO, PEDro database and Cochrane Central Register of Controlled Trials (CENTRAL) were consulted up to December 2021. Secretion clearance, static and dynamic compliance of the respiratory system(Cstat and Cdyn), airway resistance(Raw) and oxygenation outcomes were evaluated.
Thirteen studies met the study criteria, but only 12 studies were included on meta-analysis. There was no difference between VHI versus isolated aspiration for amount of secretions removed(0.41 SMD; 95% CI: -0.08 to 0.89; n=270), VHI versus MHI(0.51 grams; 95% CI: -0.08 to 1.11; n=256), VHI+VB versus VB(0.31 grams; 95% CI: -0.42 to 1.05; n=130) and VHI+VB versus isolated aspiration(0.54 grams; 95% CI: -0.06 to 1.14; n=132). There was difference for VHI versus isolated aspiration to Cstat (4.77 ml/cm HO; 95% CI: 2.41 to 7.14; n= 136).
Taking into account all studies included in meta-analysis, no evidences was found that VHI was effective in increasing the amount of secretions removed, Cdyn and oxygenation, but VHI seems to show a slight improvement in Cstat when compared to isolated aspiration. No evidence was found that VHI was effective in increasing the amount of secretions removed, Cdyn and oxygenation, but VHI seems to show a slight improvement in Cstat when compared to isolated aspiration.
明确呼吸机过度充气(VHI)对接受机械通气(MV)的成人的肺功能和分泌物清除的影响非常重要。目前尚无关于 VHI 对接受 MV 的成人的肺功能和分泌物清除影响的已发表的荟萃分析。目的:分析已发表的比较 VHI 与单纯吸引、VHI 与手动过度充气(MHI)、VHI+Vibrocompression(VB)与 VB、VHI+VB 与单纯吸引对 MV 成人的肺功能和分泌物清除的影响的随机对照试验(RCT)。
检索了以下数据库:PubMed、LILACS、EMBASE、SciELO、PEDro 数据库和 Cochrane 对照试验中心注册库(CENTRAL),检索时间截至 2021 年 12 月。评估了分泌物清除量、呼吸系统静态和动态顺应性(Cstat 和 Cdyn)、气道阻力(Raw)和氧合结局。
符合研究标准的有 13 项研究,但只有 12 项研究纳入了荟萃分析。VHI 与单纯吸引相比,分泌物清除量无差异(0.41 SMD;95%CI:-0.08 至 0.89;n=270),VHI 与 MHI(0.51 克;95%CI:-0.08 至 1.11;n=256)、VHI+VB 与 VB(0.31 克;95%CI:-0.42 至 1.05;n=130)和 VHI+VB 与单纯吸引(0.54 克;95%CI:-0.06 至 1.14;n=132)。VHI 与单纯吸引相比,Cstat 有差异(4.77 ml/cm HO;95%CI:2.41 至 7.14;n=136)。
考虑到荟萃分析中纳入的所有研究,没有证据表明 VHI 能有效增加分泌物清除量、Cdyn 和氧合,但与单纯吸引相比,VHI 似乎能略微改善 Cstat。没有证据表明 VHI 能有效增加分泌物清除量、Cdyn 和氧合,但与单纯吸引相比,VHI 似乎能略微改善 Cstat。