Suppr超能文献

评估不同浓度漂白剂对VITA ENAMIC弯曲强度和显微硬度的影响。

Evaluation of the effects of different concentrations of bleaching agents on flexural strength and microhardness of VITA ENAMIC.

作者信息

Shakibafard Mahshid, Ezoji Fariba, Esmaeili Behnaz, Bijani Ali

机构信息

Dentist, Tehran, Iran.

Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran.

出版信息

Dent Res J (Isfahan). 2022 Apr 27;19:32. eCollection 2022.

Abstract

BACKGROUND

Considering the studies on the effects of bleaching materials on properties of dental materials, The aims of this study were to evaluate the effects of two different concentrations of bleaching agents on flexural strength and microhardness of VITA ENAMIC.

MATERIALS AND METHODS

In this experimental study, 30 rectangular-shaped specimens (2 mm width × 2 mm height × 12 mm length) for flexural strength and 30 specimens (5 mm width × 5 mm length × 2 mm height) for microhardness tests were prepared from VITA ENAMIC blocks 12 × 14 × 18 mm. The specimens were polished using silicon-carbide sandpapers 400, 600, 800, 1200, 2000 under flow of water for 60 s each. The prepared samples for flexural strength and microhardness were divided into 3 subgroups ( = 10): control group (C), samples bleached using Opalescence PF 15% (B15), and samples bleached with Opalescence Xtra Boost 40% (B40). Flexural strength measurement was done using a universal testing machine, and microhardness test was done using Vickers. Data were analyzed using analysis of variance and tests and < 0.05 was considered significant.

RESULTS

The mean microhardness values of C, B15, and B40 groups were 255.46 ± 3.02, 249.86 ± 4.18, and 235.53 ± 4.61 kgf/mm. Opalescence PF 15% and Opalescence Xtra Boost 40% affected microhardness of ENAMIC significantly ( < 0.05). The mean flexural strength values of C, B15, and B40 groups were 155.26 ± 16.13, 142.14 ± 11.52, and 133.39 ± 16.13 MPa. A significant decrease in flexural strength was found between the C and B40 groups ( = 0.007). However, the difference between flexural strength of the C and B15 groups was not significant ( > 0.05).

CONCLUSION

Our study showed that both concentrations of bleaching agents can affect microhardness of ENAMIC. Moreover, hydrogen peroxide 40% has a negative effect on the flexural strength of ENAMIC.

摘要

背景

考虑到关于漂白材料对牙科材料性能影响的研究,本研究的目的是评估两种不同浓度的漂白剂对VITA ENAMIC弯曲强度和显微硬度的影响。

材料与方法

在本实验研究中,从尺寸为12×14×18mm的VITA ENAMIC块体中制备30个用于弯曲强度测试的矩形试样(宽2mm×高2mm×长12mm)和30个用于显微硬度测试的试样(宽5mm×长5mm×高2mm)。使用400、600、800、1200、2000号碳化硅砂纸在水流下对试样各打磨60秒进行抛光。将制备好的用于弯曲强度和显微硬度测试的样品分为3个亚组(每组n = 10):对照组(C)、用15%Opalescence PF漂白的样品(B15)以及用40%Opalescence Xtra Boost漂白的样品(B40)。使用万能试验机进行弯曲强度测量,使用维氏硬度计进行显微硬度测试。数据采用方差分析和t检验进行分析,P < 0.05被认为具有统计学意义。

结果

C组、B15组和B40组的平均显微硬度值分别为255.46±3.02、249.86±4.18和235.53±4.61 kgf/mm²。15%Opalescence PF和40%Opalescence Xtra Boost对ENAMIC的显微硬度有显著影响(P < 0.05)。C组、B15组和B40组的平均弯曲强度值分别为155.26±16.13、142.14±11.52和133.39±16.13MPa。C组和B40组之间的弯曲强度有显著降低(P = 0.007)。然而,C组和B15组之间的弯曲强度差异不显著(P > 0.05)。

结论

我们的研究表明,两种浓度的漂白剂都会影响ENAMIC的显微硬度。此外,40%的过氧化氢对ENAMIC的弯曲强度有负面影响。