文献检索文档翻译深度研究
Suppr Zotero 插件Zotero 插件
邀请有礼套餐&价格历史记录

新学期,新优惠

限时优惠:9月1日-9月22日

30天高级会员仅需29元

1天体验卡首发特惠仅需5.99元

了解详情
不再提醒
插件&应用
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
高级版
套餐订阅购买积分包
AI 工具
文献检索文档翻译深度研究
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2025

氟脱氧葡萄糖正电子发射断层扫描/计算机断层扫描诊断人工关节周围感染准确性的系统评价与Meta分析

A Systematic Review and Meta-Analysis on the Accuracy of Fluorodeoxyglucose Positron Emission Tomography/ Computerized Tomography for Diagnosing Periprosthetic Joint Infections.

作者信息

Hu Mei, Chen Guangwen, Luo Lin, Shang Lan

机构信息

Department of Radiology, Sichuan Provincial People's Hospital, Sichuan Academy of Medical Sciences, Chengdu, China.

出版信息

Front Surg. 2022 Jun 1;9:698781. doi: 10.3389/fsurg.2022.698781. eCollection 2022.


DOI:10.3389/fsurg.2022.698781
PMID:35722526
原文链接:https://pmc.ncbi.nlm.nih.gov/articles/PMC9198456/
Abstract

OBJECTIVE: Fluorodeoxyglucose Positron emission tomography/computerized tomography (FDG PET/CT) has become popular for diagnosing periprosthetic joint infections (PJI). However, the diagnostic accuracy for this technique has varied from report to report. This meta-analysis was performed to assess the accuracy of FDG PET/CT for PJI diagnosis. MATERIAL AND METHODS: We conducted a systematic search of online academic databases for all studies reporting the diagnostic accuracy of FDG PET/CT for PJI. Meta-analysis was performed using STATA software. RESULTS: 23 studies, containing data on 1,437 patients, met inclusion criteria. Pooled sensitivity and specificity of FDG PET/CT for diagnosing PJI were 85% (95% CI, 76%, 91%) and 86% (95% CI, 78%, 91%), respectively with an AUC of 0.92. LRP was 6.1 (95% CI, 3.8, 9.7) and LRN was 0.17 (0.11, 0.28), indicating that FDG PET/CT cannot be used for confirmation or exclusion of PJI. There was significant inter-study heterogeneity, but no significant publication bias was noted. CONCLUSIONS: Our study found that FDG PET/CT has an important role as a diagnostic tool for PJI with high sensitivity and specificity. Further studies exploring its accuracy in different PJI locations remain necessary.

摘要

目的:氟脱氧葡萄糖正电子发射断层扫描/计算机断层扫描(FDG PET/CT)在诊断人工关节周围感染(PJI)方面已变得很普遍。然而,该技术的诊断准确性在不同报告中有所不同。本荟萃分析旨在评估FDG PET/CT诊断PJI的准确性。 材料与方法:我们对在线学术数据库进行了系统检索,以查找所有报告FDG PET/CT诊断PJI准确性的研究。使用STATA软件进行荟萃分析。 结果:23项研究符合纳入标准,包含1437例患者的数据。FDG PET/CT诊断PJI的合并敏感性和特异性分别为85%(95%CI,76%,91%)和86%(95%CI,78%,91%),AUC为0.92。阳性似然比为6.1(95%CI,3.8,9.7),阴性似然比为0.17(0.11,0.28),表明FDG PET/CT不能用于确诊或排除PJI。研究间存在显著异质性,但未发现显著的发表偏倚。 结论:我们的研究发现,FDG PET/CT作为一种诊断工具,在PJI诊断中具有重要作用,具有较高的敏感性和特异性。进一步研究其在不同PJI部位的准确性仍然很有必要。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/4d604c3d4147/fsurg-09-698781-g009.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/9309f8e157d0/fsurg-09-698781-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/f4ee80ac216c/fsurg-09-698781-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/257ad770366a/fsurg-09-698781-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/59f69d5b9c0e/fsurg-09-698781-g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/7925fea091fa/fsurg-09-698781-g005.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/7e5286ff6827/fsurg-09-698781-g006.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/c29c86003409/fsurg-09-698781-g007.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/52845226af73/fsurg-09-698781-g008.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/4d604c3d4147/fsurg-09-698781-g009.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/9309f8e157d0/fsurg-09-698781-g001.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/f4ee80ac216c/fsurg-09-698781-g002.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/257ad770366a/fsurg-09-698781-g003.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/59f69d5b9c0e/fsurg-09-698781-g004.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/7925fea091fa/fsurg-09-698781-g005.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/7e5286ff6827/fsurg-09-698781-g006.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/c29c86003409/fsurg-09-698781-g007.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/52845226af73/fsurg-09-698781-g008.jpg
https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5334/9198456/4d604c3d4147/fsurg-09-698781-g009.jpg

相似文献

[1]
A Systematic Review and Meta-Analysis on the Accuracy of Fluorodeoxyglucose Positron Emission Tomography/ Computerized Tomography for Diagnosing Periprosthetic Joint Infections.

Front Surg. 2022-6-1

[2]
18F FDG-PET/CT has poor diagnostic accuracy in diagnosing shoulder PJI.

Eur J Nucl Med Mol Imaging. 2019-7-11

[3]
Diagnostic accuracy of positron emission tomography/computerized tomography for periprosthetic joint infection of hip: systematic review and meta-analysis.

J Orthop Surg Res. 2023-8-30

[4]
The value of F-FDG PET/CT for the diagnosis of device-related infections in patients with a left ventricular assist device: a systematic review and meta-analysis.

Eur J Nucl Med Mol Imaging. 2021-1

[5]
Whole-Body F-FDG PET and F-FDG PET/CT in Patients with Suspected Paraneoplastic Syndrome: A Systematic Review and Meta-Analysis of Diagnostic Accuracy.

J Nucl Med. 2016-12-15

[6]
Fluorodeoxyglucose positron emission tomography imaging for diagnosing periprosthetic hip infection: the importance of diagnostic criteria.

Int Orthop. 2018-9

[7]
Diagnostic value of using 18F-FDG PET and PET/CT in immunocompetent patients with primary central nervous system lymphoma: A systematic review and meta-analysis.

Oncotarget. 2017-6-20

[8]
Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection: A Systematic Review and Meta-Analysis.

Circ Cardiovasc Imaging. 2017-4

[9]
The diagnostic accuracy of 18F-fluorodeoxyglucose positron emission tomography and computed tomography in staging bladder cancer: a single-institution study and a systematic review with meta-analysis.

World J Urol. 2016-9

[10]
Diagnostic Accuracy of FDG PET/CT in Suspected LVAD Infections: A Case Series, Systematic Review, and Meta-Analysis.

JACC Cardiovasc Imaging. 2020-5

引用本文的文献

[1]
Artificial Intelligence and Its Role in Predicting Periprosthetic Joint Infections.

Biomedicines. 2025-7-30

[2]
From image to index: diagnostic accuracy of a novel semi-quantitative approach for assessing suspected periprosthetic joint infection with triple-phase bone scintigraphy.

Ann Nucl Med. 2025-6-26

[3]
Imaging in Periprosthetic Joint Infection Diagnosis: A Comprehensive Review.

Microorganisms. 2024-12-24

[4]
Research trends and focus of prosthetic joint infections from 2013 to 2023: bibliometric and visualization studies.

Front Microbiol. 2024-12-20

[5]
EANM/SNMMI guideline/procedure standard for [F]FDG hybrid PET use in infection and inflammation in adults v2.0.

Eur J Nucl Med Mol Imaging. 2025-1

[6]
Accuracy of Albumin, Globulin, and Albumin-Globulin Ratio for Diagnosing Periprosthetic Joint Infection: A Systematic Review and Meta-Analysis.

J Clin Med. 2023-12-5

[7]
Diagnostic accuracy of positron emission tomography/computerized tomography for periprosthetic joint infection of hip: systematic review and meta-analysis.

J Orthop Surg Res. 2023-8-30

[8]
Emerging Technologies in Diagnosing Periprosthetic Joint Infections.

Indian J Orthop. 2023-4-17

本文引用的文献

[1]
F-FDG PET for Diagnosing Infections in Prosthetic Joints.

PET Clin. 2020-4

[2]
Diagnosis and Prevention of Periprosthetic Joint Infections.

J Am Acad Orthop Surg. 2020-4-15

[3]
Periprosthetic joint infection: current concepts and outlook.

EFORT Open Rev. 2019-7-29

[4]
Diagnostic utility of fluorodeoxyglucose positron emission tomography in prosthetic joint infection based on MSIS criteria.

Bone Joint J. 2019-8

[5]
18F FDG-PET/CT has poor diagnostic accuracy in diagnosing shoulder PJI.

Eur J Nucl Med Mol Imaging. 2019-7-11

[6]
Consensus document for the diagnosis of prosthetic joint infections: a joint paper by the EANM, EBJIS, and ESR (with ESCMID endorsement).

Eur J Nucl Med Mol Imaging. 2019-1-26

[7]
Fluorodeoxyglucose positron emission tomography imaging for diagnosing periprosthetic hip infection: the importance of diagnostic criteria.

Int Orthop. 2018-9

[8]
Hip and Knee Replacements: A Neglected Potential Savings Opportunity.

JAMA. 2018-3-13

[9]
Added value of 18F-FDG PET/CT in diagnosing infected hip prosthesis.

Acta Radiol. 2018-5

[10]
What is the Accuracy of Nuclear Imaging in the Assessment of Periprosthetic Knee Infection? A Meta-analysis.

Clin Orthop Relat Res. 2017-5

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

推荐工具

医学文档翻译智能文献检索