National Clinical Research Center for Digestive Diseases, Department of Gastroenterology, Changhai Hospital, Naval Medical University, Shanghai, China.
Department of Gastroenterology, Qilu Hospital of Shandong University, Jinan, Shandong, China.
Endoscopy. 2023 Jan;55(1):52-57. doi: 10.1055/a-1881-4369. Epub 2022 Jul 12.
Certain patients experience difficulty swallowing a video capsule endoscopy (VCE) device owing to its relatively large size. The newly developed small-sized magnetically controlled capsule endoscopy (MCE) device is the smallest VCE device ever reported. We aimed to evaluate the performance of the small-sized MCE device in terms of ingestion and examination efficacy. METHODS : Patients in two centers were prospectively enrolled and randomized to the small-sized or standard MCE groups. Differences in capsule ingestion difficulties, visualization of the gastrointestinal tract, and capsule transit times were compared. RESULTS : 96 patients were enrolled (48 in each group). In the small-sized MCE group, the mean (SD) difficulty score and time to swallow the capsule, and success rate for swallowing the capsule at the first attempt were 0.6 (1.0), 3.4 (1.3) seconds, and 89.6 %, which was significant better compared with the standard MCE group with 3.1 (1.7), 12.0 (14.3) seconds and 60.4 %, respectively (all < 0.001). Visualization of the esophagus, stomach, and small bowel were comparable between the two groups. The small-sized MCE group had a significantly shorter gastric transit time (49.4 minutes vs. 66.2 minutes; = 0.04) and longer small-bowel transit time (5.8 hours vs. 5.0 hours; = 0.045). CONCLUSIONS : The small-sized MCE device is feasible and safe for gastrointestinal examination, alleviating difficulties in capsule ingestion, improving gastric emptying under magnetic control, and prolonging the small-bowel transit time.
由于视频胶囊内镜(VCE)设备相对较大,某些患者在吞咽时会遇到困难。新开发的小型磁控胶囊内镜(MCE)设备是迄今为止报道的最小 VCE 设备。我们旨在评估小型 MCE 设备在摄取和检查效果方面的性能。
两个中心的患者前瞻性入组并随机分为小型或标准 MCE 组。比较了胶囊摄取困难、胃肠道可视化和胶囊通过时间的差异。
96 例患者入组(每组 48 例)。在小型 MCE 组中,平均(SD)吞咽胶囊的难度评分和时间分别为 0.6(1.0)秒和 3.4(1.3)秒,首次尝试吞咽胶囊的成功率为 89.6%,这明显优于标准 MCE 组的 3.1(1.7)秒和 12.0(14.3)秒和 60.4%(均 < 0.001)。两组食管、胃和小肠的可视化效果相当。小型 MCE 组的胃转运时间明显缩短(49.4 分钟比 66.2 分钟; = 0.04),小肠转运时间延长(5.8 小时比 5.0 小时; = 0.045)。
小型 MCE 设备可用于胃肠道检查,安全可行,可减轻胶囊摄取困难,改善磁控下胃排空,并延长小肠转运时间。