Suppr超能文献

比较单次激发、分段读出和 Zoomit 回波平面成像在 3T 肾脏扩散加权成像中的临床应用。

Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T.

机构信息

Department of Radiology, Xiangya Hospital, Central South University, No. 87 Xiangya Rd., Kai Fu District, Changsha, 410008, Hunan, People's Republic of China.

National Clinical Research Center for Geriatric Disorders, Xiangya Hospital, Central South University, Changsha, 410008, Hunan, People's Republic of China.

出版信息

Sci Rep. 2022 Jul 20;12(1):12389. doi: 10.1038/s41598-022-16670-w.

Abstract

We compared the clinical utility of single-shot echo-planar imaging (SS-EPI) using different breathing schemes, readout-segmented EPI and zoomit EPI in the repeatability of apparent diffusion coefficient (ADC) measurements, cortico-medullary contrast to noise ratio (c-mCNR) and image quality. In this institutional review board-approved prospective study, some common clinically applicable diffusion-weighted imaging (b = 50, 400, 800 s/mm) of kidney on 3.0 T MRI were performed on 22 volunteers using SS-EPI with breath-hold diffusion-weighted imaging (BH-DWI), free-breathing (FB-DWI), navigator-triggered (NT-DWI) and respiratory-triggered (RT-DWI), readout-segmented DWI (RS-DWI), and Zoomit DWI (Z-DWI). ADC and c-mCNR were measured in 12 anatomic locations (the upper, middle, and lower pole of the renal cortex and medulla), and image quality was assessed on these DWI sequences. A DWI with the optimal clinical utility was decided by systematically assessing the ADC repeatability, c-mCNR and image quality among the DWIs. For ADC measurements, Z-DWI had an excellent intra-observer agreement (intra-class correlation coefficients (ICCs): 0.876-0.944) and good inter-observer agreement (inter-class ICCs: 0.798-0.856) in six DWI sequences. Z-DWI had the highest ADC repeatability in most of the 12 anatomic locations of the kidneys (mean ADC absolute difference: 0.070-0.111 × 10 mm/s, limit of agreement: 0.031-0.056 × 10 mm/s). In all DWIs, Z-DWI yielded a slightly higher c-mCNR than other DWIs in most representative locations (P > 0.05), which was significantly higher than BH-DWI and FB-DWI in the middle pole of both kidneys and the upper pole of the left kidney (P < 0.05). In addition, Z-DWI yielded image quality that was similar to RT-DWI and NT-DWI (P > 0.05) and superior to BH-DWI, FB-DWI and RS-DWI (P < 0.05). Our results suggest that Z-DWI provides the highest ADC reproducibility, better c-mCNR and good image quality on 3.0 T MRI, making it the recommended sequence for clinical DWI of the kidney.

摘要

我们比较了单次激发回波平面成像(SS-EPI)在不同呼吸方案(读取分段 EPI 和 Zoomit EPI)下,在表观扩散系数(ADC)测量的重复性、皮质-髓质对比噪声比(c-mCNR)和图像质量方面的临床应用。在这项机构审查委员会批准的前瞻性研究中,对 22 名志愿者在 3.0T MRI 上使用 SS-EPI 进行了单次激发扩散加权成像(BH-DWI)、自由呼吸(FB-DWI)、导航触发(NT-DWI)和呼吸触发(RT-DWI)、读取分段 DWI(RS-DWI)和 Zoomit DWI(Z-DWI)的常规临床应用扩散加权成像(b=50、400、800 s/mm)。在这些 DWI 序列中测量了 12 个解剖位置(肾脏皮质和髓质的上极、中极和下极)的 ADC 和 c-mCNR,并评估了图像质量。通过系统评估 DWIs 中的 ADC 重复性、c-mCNR 和图像质量,决定了具有最佳临床效用的 DWI。对于 ADC 测量,Z-DWI 在六个 DWI 序列中具有出色的观察者内一致性(组内相关系数(ICCs):0.876-0.944)和良好的观察者间一致性(组间 ICCs:0.798-0.856)。Z-DWI 在肾脏的大多数 12 个解剖位置中具有最高的 ADC 重复性(平均 ADC 绝对差异:0.070-0.111×10mm/s,一致性界限:0.031-0.056×10mm/s)。在所有 DWIs 中,Z-DWI 在大多数代表性位置的 c-mCNR 略高于其他 DWIs(P>0.05),在双侧肾脏的中极和左肾的上极,Z-DWI 明显高于 BH-DWI 和 FB-DWI(P<0.05)。此外,Z-DWI 的图像质量与 RT-DWI 和 NT-DWI 相似(P>0.05),优于 BH-DWI、FB-DWI 和 RS-DWI(P<0.05)。我们的结果表明,Z-DWI 在 3.0T MRI 上提供了最高的 ADC 可重复性、更好的 c-mCNR 和良好的图像质量,使其成为肾脏临床 DWI 的推荐序列。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fd2e/9300617/b0a2847c0aae/41598_2022_16670_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验