Physical and mechanical properties of three different (Ketac Molar Easymix, Dyract XP, Cention N (CN)) restoratives with different ingredients were evaluated.
Four groups were obtained; Group 1: CN LightCure, Group 2: CN SelfCure, Group 3: Ketac Molar Easymix and Group 4: Dyract XP. Disk-shaped samples (n = 10) were prepared and evaluated for the surface roughness test using a profilometer. For the flexure strength test, 2 × 2 × 25 mm bar-shaped samples (n = 10) were prepared, and a three-point bending test was applied to the samples. After preparing cavities for microleakage tests, teeth were restored with restoratives, immersed in dye, and microleakage was assessed. For the microtensile bond strength (µTBS) test, ten sticks were obtained for each group and were stressed under tension.
According to surface roughness tests, CN SelfCure showed the lowest value (0.13 μm), while Ketac Molar Easymix showed the highest value (0.28 μm), and significant differences were found between the groups. In flexural strength tests, the highest values were seen in CN SelfCure (82.94 MPa), with statistically significant differences between the groups. When CN SelfCure was applied with an adhesive, the teeth showed statistically decreased leakage than other groups on the gingival side. Higher leakage values were seen on the gingival side than the occlusal side in most groups, and the SelfCure groups showed decreased leakage than the LightCure groups. According to µTBS tests, the highest value was obtained in CN SelfCure-Adhesive group, while the lowest was in CN LightCure-Non-adhesive group. When µTBS was evaluated regardless of adhesive use, the SelfCure groups showed higher µTBS values than the LightCure groups. As a result of the µTBS and microleakage test, the difference between the use of CN with and without adhesive, regardless of the polymerization type, was found to be significant (p < 0.05).
Cention N showed better properties in SelfCure mode, compared to the rest materials tested, but further in vitro and in vivo studies are needed to investigate the effect of different polymerization modes and the oral environmental conditions.
评估三种不同成分的(Ketac Molar Easymix、Dyract XP、Cention N(CN))修复材料的物理和机械性能。
共获得 4 组;第 1 组:CN 光固化,第 2 组:CN 自固化,第 3 组:Ketac Molar Easymix,第 4 组:Dyract XP。制备盘状样品(n=10),并用轮廓仪进行表面粗糙度测试。对于弯曲强度测试,制备 2×2×25mm 棒状样品(n=10),对样品进行三点弯曲测试。为了进行微渗漏测试,制备了用于微渗漏测试的腔,用修复材料修复牙齿,浸入染料,并评估微渗漏。对于微拉伸粘结强度(µTBS)测试,从每个组中获得 10 个棒,并在张力下进行受力。
根据表面粗糙度测试,CN 自固化的数值最低(0.13μm),而 Ketac Molar Easymix 的数值最高(0.28μm),各组之间存在显著差异。在弯曲强度测试中,CN 自固化的数值最高(82.94MPa),各组之间存在统计学差异。当 CN 自固化与粘结剂一起使用时,与其他组相比,牙在牙龈侧的渗漏明显减少。大多数组的牙龈侧漏值高于咬合侧,自固化组的漏值低于光固化组。根据 µTBS 测试,CN 自固化-粘结剂组的数值最高,而 CN 光固化-非粘结剂组的数值最低。当不考虑粘结剂的使用评估 µTBS 时,自固化组的 µTBS 值高于光固化组。由于 µTBS 和微渗漏测试,无论聚合类型如何,使用 CN 与不使用 CN 之间的差异均具有统计学意义(p < 0.05)。
与测试的其他材料相比,Cention N 在自固化模式下表现出更好的性能,但需要进一步的体外和体内研究来研究不同聚合模式和口腔环境条件的影响。