Suppr超能文献

用于猫的犬类单核细胞趋化蛋白-1 ELISA 分析性能评估及正常体重和肥胖猫循环水平检测。

Analytical performance of a canine ELISA monocyte chemoattractant protein-1 assay for use in cats and evaluation of circulating levels in normal weight and obese cats.

机构信息

Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Dyrlægevej 16, 1870, Frederiksberg, Denmark.

AniCura Vangede Animal Hospital, Plantevej 2, 2870, Dyssegård, Denmark.

出版信息

Acta Vet Scand. 2022 Sep 5;64(1):22. doi: 10.1186/s13028-022-00640-3.

Abstract

BACKGROUND

In human and murine obesity, adipose tissue dwelling macrophages and adipocytes produce monocyte chemoattractant protein-1 (MCP-1) leading to systemic low-grade inflammation. The aim of the study was to validate a canine MCP-1 ELISA assay for use in cats and to investigate whether a difference in MCP-1 concentrations could be detected between: a) cats having normal or elevated circulating serum amyloid A (SAA) levels and b) normal weight and obese cats. Serum obtained from 36 client-owned cats of various breed, age and sex with normal (n = 20) to elevated SAA (n = 16) was used for the validation of the canine MCP-1 ELISA assay. As no golden standard exists for measurement of inflammation, circulating MCP-1 concentrations were compared to SAA measurements, as an indicator of systemic inflammation. Analytical precision, dilution recovery and detection limit were calculated. A possible correlation between MCP-1 concentrations and obesity related measures (body fat percentage (BF%), insulin sensitivity and cytokine expression) were investigated in another population of 73 healthy, lean to obese, neutered domestic short-haired cats.

RESULTS

Intra- (2.7-4.1%) and inter-assay (2.2-3.6%) coefficient of variation and dilution recovery were acceptable, and the detection limit was 27.1 pg/mL. MCP-1 did not correlate with SAA, and there was no difference between the inflammatory (SAA > 20 mg/L) and non-inflammatory group, due to a marked overlap in MCP-1 concentrations. Circulating MCP-1 concentrations were unaffected by BF% (r = 2.7 × 10, P = 0.21) and other obesity-related markers.

CONCLUSIONS

The present canine ELISA assay seems to be able to measure circulating feline MCP-1. However, further studies are needed to determine its possible use for detecting inflammation in relation to disease processes or obesity-related low-grade inflammation in cats.

摘要

背景

在人类和鼠类肥胖中,脂肪组织驻留的巨噬细胞和脂肪细胞产生单核细胞趋化蛋白-1(MCP-1),导致全身低度炎症。本研究的目的是验证一种可用于猫的犬 MCP-1 ELISA 检测法,并探讨以下两种情况之间 MCP-1 浓度是否存在差异:a)血清淀粉样蛋白 A(SAA)水平正常或升高的猫和 b)正常体重和肥胖的猫。本研究使用了来自 36 只不同品种、年龄和性别的客户拥有的猫的血清,这些猫的 SAA 水平正常(n = 20)或升高(n = 16),用于验证犬 MCP-1 ELISA 检测法。由于目前尚无炎症的金标准,因此将循环 MCP-1 浓度与 SAA 测量值进行比较,作为全身炎症的指标。计算了分析精密度、稀释回收率和检测限。在另一组 73 只健康、瘦至肥胖、去势的家养短毛猫中,研究了 MCP-1 浓度与肥胖相关指标(体脂肪百分比(BF%)、胰岛素敏感性和细胞因子表达)之间的可能相关性。

结果

该方法的内(2.7-4.1%)和间(2.2-3.6%)分析变异系数和稀释回收率可接受,检测限为 27.1 pg/mL。MCP-1 与 SAA 不相关,由于 MCP-1 浓度存在明显重叠,因此在炎症(SAA>20 mg/L)和非炎症组之间没有差异。循环 MCP-1 浓度不受 BF%(r = 2.7×10,P = 0.21)和其他肥胖相关标志物的影响。

结论

目前的犬 ELISA 检测法似乎能够测量循环猫 MCP-1。然而,需要进一步的研究来确定其是否可用于检测与疾病过程或猫肥胖相关低度炎症相关的炎症。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验